Programming Procedure
any loads connected to the outputs should be disconnected before programming to avoid inadvertent activations.
After entering programming mode, the device remains until correct completion of the procedure. Otherwise the power supply
must be disconnected or press RES to exit.
1. Press keys RES and P2 at the same time
2. Release key RES keeping key P2 pressed until led S1 illuminates.
3. Subsequent activation of key P2 illuminates in sequence the leds S2, A, B and so on, to enable selection of the output
and/or parameter to be programmed as described in Table 3. Each time P2 is pressed, there is approx. 5 seconds in which
to modify the selection as required.
Parameter to program
Code and Time of activation of Output 1 S1
Code and Time of activation of Output 2 S2
Code and Time of activation of Output 3 A
Code and Time of activation of Output 4 B
Initial User and Final User
Device Number
Table 3. Illumination of leds in programming mode
4. A brief flash of the led/s indicates that the selection has been made
Follow one of the procedures below on the basis of the type of programming selected:
5a Programming of output code and activation time:
a. At this point the command and/or activation number must be sent to the device 170F via a digibus device (pane or interpho-
ne) or programmer 950B or device in the digital intercommunication series (6221, 6935/A) or suitable PC software.
b. A brief flash indicates that the code has been received correctly and that it is on standby for the activation time setting.
c. The time (from 1 to 9999 in seconds) can be entered via the devices described above or by interrupting the self-learning
process by pressing key P1. In fact from the time the flashing starts as described in point B, 170F starts to count the
seconds of activation to be programmed until the key P1 is pressed.
5b Programming Initial User and Final User:
a.
Enter the number of the initial user via the numerical keypad and send it to the device.
b.
A brief flash confirms reception
c.
Enter the number of the final user via the numerical keypad and send it to the device..
d.
The leds switch off on completion of programming
5c Device Number Programming:
a.
Enter the number via the numerical keypad and send it to the device.
b.
The leds switch off on completion of programming
Example 1: Activation of output 3 of 170F for 5 seconds after delivery of a command LOCK from an interphone of a DIGIBUS
system within the interval 4000 - 6000 of Initial User and Final User.
Set the Dip-Switches as specified in Table 1 , item "Window activation"
First of all the limits of the Initial User and Final User on the 170F must be programmed. Then follow the programming procedu-
re illuminating all 4 leds and entering the number 4000 on the numerical keypad of a panel and then, after the leds flash, enter
the number 6000. Alternatively the programmer 950B or PC could be used or the user could press the keys on a panel with sin-
gle keys previously programmed with the software numbers 4000 and 6000.
To enable delivery of the Lock command from a digibus interphone, the latter must be active, after which any other interphone
in the system can be called. If the programmer or PC is used this operation is not necessary.
At this point set output 3 to programming mode illuminating led A, press the Lock key of the interphone (or send the command)
and then set the activation time by pressing the key P1 5 seconds after the start of flashing or by sending the number 5 from a
panel or the programmer or also from the interphone number 5 of the system. Led A turns off to indicate the end of the program-
ming procedure.
Example 2:
Activation of output 4 of 170F in ON/OFF mode after reception of the command STAIR LIGHT
interphone type 6221 number 4578.
Set the Dip-Switches DIP1 to ON ; DIP2 to OFF ; DIP3 to OFF ; DIP4 to ON
At this point set output 4 to programming mode illuminating led B only. After the flash press the stair light key
interphone type 6221 number 4578. In this case the activation time is irrelevant but the device remains on standby to receive
the number of activation seconds. Then press P1 on 170F or make a call from the entrance panel or press a function key on an
interphone. Led B turns off to indicate the end of the programming procedure. Each time the "Stair light" key is pressed on
interphone number 4578 output 4 changes status (if deactivated it activates and vice versa)