Juego de mantenimiento general, clavadora de acabado recta

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

DANGER:
Do not use oxygen, combustible gases, or bottled gases as a power source for this tool. The tool will explode and cause
death or serious injury.
WARNING:
To reduce the risk of injury, the user must read and understand the operator's manual before using this product. If the operator's
manual which originally accompanied this tool is missing, visit us at www.ridgid.com or call 1-866-539-1710.
WARNING:
Disconnect the tool from the air supply before performing maintenance on this tool. Failure to do so could result in serious
personal injury.
WARNING:
The operation of any power tool can result in foreign objects being thrown into your eyes, which can result in severe eye
damage. Before beginning power tool operation, always wear safety goggles or safety glasses with side shields, or a full face
shield when needed. We recommend Wide Vision Safety Mask for use over eyeglasses or standard safety glasses with side
shields. Always use eye protection which is marked to comply with ANSI Z87.1.
PLIERS
RIB
2
3
4
24
1
13
23
7
9
8
10
11
12
THIS KIT INCLUDES:
Seal (7)
O-Rings (8, 11, 18)
Collar (12)
Cylinder Cap Seal (13)
Piston Ring (14)
Cylinder Ring (20)
Tools needed (but not included): 1/8-in. punch for removing head
valve assembly, and 2.5 mm punch for removing trigger pivot pin.
REMOVING AND REPLACING O-RINGS AND SEALS
See Figures 1 - 3.
1. Disconnect the tool from the air supply and remove any fasteners
Fig. 1
2. Using a 4 mm hex key, remove the four screws (1) from the top
Valve Assembly
3. Remove the cylinder cap seal (13).
Includes
4. Remove the press ring (17).
Key No. 7-12
5. With two pair of needle-nose pliers, gently grasp the ribs of the
6. Remove the driver (16) from the cylinder (19) and set both aside.
7. Remove the muffler cap using a 4 mm hex key and set aside.
6
8. Using a 1/8-in. punch, gently push the valve assembly out of the
9. Separate the seal (7) from the head valve.
10. Remove o-rings (8, 11) from the head valve piston.
11. Remove collar (12).
12. Clean all parts with a dry, clean cloth.
13. Apply a light coat of grease to new o-rings (8, 11) and install.
Key No. 10
With Items 8, 9,
14. Reassemble parts in the order shown in Figure 2.
and 11
15. Push head valve assembly into cap, applying sufficient pressure
Installed
16. Reinstall muffler assembly onto cap.
17. Set aside tool cap and proceed with cylinder maintenance.
Fig. 2
OVERHAUL KIT
R250SFA Straight Finish Nailer
that remain in the tool.
cap (6) of the tool. Remove the top cap.
cylinder (on opposing sides) and pull the cylinder (19) from the tool
body.
cap through the holes in the top of the cap.
to insure the seal (7) and the collar (12) snap into position.
PSF0003
Bumper (21)
Retainer (41)
Trigger Valve Assembly (99)
Grease
Overhaul Kit Instruction Sheet

Publicidad

loading

Resumen de contenidos para RIDGID R250SFA

  • Página 1 WARNING: To reduce the risk of injury, the user must read and understand the operator’s manual before using this product. If the operator’s manual which originally accompanied this tool is missing, visit us at www.ridgid.com or call 1-866-539-1710. WARNING: Disconnect the tool from the air supply before performing maintenance on this tool. Failure to do so could result in serious personal injury.
  • Página 2 8. Reinstall the trigger pivot pin (42) and the retainer (41). SIZING GUIDE Fig. 3 Fig. 4 Fig. 5 ONE WORLD TECHNOLOGIES, INC. P.O. Box 35, Hwy. 8, Pickens, SC 29671 983000-669 1-866-539-1710 3-30-06 RIDGID is a registered trademark of RIDGID, Inc. and used under license. (REV:01) ®...
  • Página 3: Kit De Remise À Neuf

    AVERTISSEMENT : Pour réduire les risques de blessures, l’utilisateur doit lire et veiller à bien comprendre le manuel d’utilisation avant d’utiliser ce produit. Si le manuel d’utilisation qui accompagnait initialement cet outil est absent, visiter www.ridgid.com ou appeler 1-866-539-1710. AVERTISSEMENT : Débrancher l’outil de l’arrivée d’air avant tout entretien de cet outil.
  • Página 4: Entretien Du Cylindre

    8. Réinstaller l’axe de pivot de gâchette (42) et la retenue (41). GUIDE DE DIMENSIONNEMENT Fig. 4 Fig. 5 ONE WORLD TECHNOLOGIES, INC. P.O. Box 35, Hwy. 8, Pickens, SC 29671, États-Unis 983000-669 1-866-539-1710 3-30-06 (REV:01) RIDGID est une marque déposée de RIDGID, Inc., utilisée sous licence. ®...
  • Página 5: Juego De Mantenimiento General

    Para reducir el riesgo de lesiones, el usuario debe leer y comprender el manual del operador antes de usar este producto. Si falta el manual del operador incluido originalmente con esta herramienta, visite nuestro sitio, www.ridgid.com, o llame al 1-866-539-1710.
  • Página 6: Mantenimiento Del Cilindro

    Fig. 3 GUÍA DE TAMAÑOS Fig. 4 Fig. 5 ONE WORLD TECHNOLOGIES, INC. P.O. Box 35, Hwy. 8, Pickens, SC 29671, USA 983000-669 1-866-539-1710 3-30-06 RIDGID es una marca comercial registrada de RIDGID, Inc., y es empleada mediante autorización. (REV:01) ®...