Descargar Imprimir esta página

Error Codes - Adam Cruiser CKT Serie Manual Del Usuario

Publicidad

Idiomas disponibles

Idiomas disponibles

Pressing the [0] key will escape for the date and time settings with the current values
unchanged. It is possible to change only the time by setting a new time, then pressing the
[0] key when the date settings are shown.

10.0 ERROR CODES

During the initial power-on testing or during operation, the scale may show an error message.
If an error message is shown please consult the table below, following the steps related to
the error code on the scale display. If the error message is still shown then contact your dealer
for support.
ERROR
DESCRIPTION
CODE
Err 1
Time input Error
Err 2
Date input Error
Err 3
Zero when power on and not stable.
Err 4
Initial Zero is greater than allowed
(4% of maximum capacity) when
power is turned on or when the
[Zero/Enter] key is pressed.
Err 5
Zeroing error
Err 6
Negative tare error
Err 7
Stability error
Err 8
Percent input error
Err 9
User zero calibrate exceed factory
calibration 10%
Err 10
User load calibration exceed factory
calibration 10%
Err 19
Weight lower limit is larger than upper
limit
Err ADC
Incorrect ADC value
---OL---
Weight over range
---Lo---
Below Gross zero by >20e
© Adam Equipment Company 2019
POSSIBLE CAUSES
Invalid time entry such as "268970" for the time
format "H-m-S".
th
34
day of a month is an invalid entry.
Scale not placed on a stable surface
Weight on the pan when turning the scale on.
Excessive weight on the pan when zeroing the
scale.
Platform is not installed.
Improper calibration of the scale.
Damaged load cell.
Damaged Electronics.
Trying to zero too much mass
Pressing tare with a negative value
Draft or vibrations causes unstable weight
Percent function is entered with no reference
mass on the pan.
Improper calibration (should be within +10% of
the factory calibration). The old calibration data
will be retained until the calibration process is
complete.
Improper calibration (should be within +10% of
the factory calibration). The old calibration data
will be retained until the calibration process is
complete.
High limit is set first, then the low limit is set
higher than the high limit and low limit not equal
to zero.
Load cell is damaged.
Electronics is damaged.
Weight over scale range
Weight below scale range
19

Publicidad