Maintenance
Replacing Transducers
WARNING: Always press the Main switch to the
OFF position and disconnect the power supply
before cleaning the water sump.
!
NOTE: The transducers are fixed in the water
sump with plastic clips.
To replace the transducers:
1.
Remove the front glass and fuel bed (see the
instructions in the section "Preparing the Fireplace
for Placement" on page 8).
2.
Disconnect the fill cap (turn clockwise).
3.
Disconnect the 2 connectors, located on the right
side of the water sump.
4
. Release the 2 clips on both sides and remove the
nozzle.
5.
Press the clip back and lift the transducer
upwards out of its holder.
6.
Place the new transducers.
7.
Repeat the steps above in reverse order to
reassemble.
Cleaning Mesh Filter
1.
Turn off the water supply.
2.
Close the ball valves.
3.
Unscrew the base and clean the filter inside.
Replacing In-line Filter
1.
Turn off the water supply.
2.
Close the ball valves.
3.
Replace the in-line filter.
!
NOTE: Be sure to place the filter in correct
alignment. Match the "flow" direction marking on
the filter.
21