MAINTENANCE
The flames should look like those in Figure 9. To clean the burner,
use a soft brush after the burner has cooled completely. Never use a
vacuum cleaner on the burner. It is recommended to store the fire pit
indoors during winter if it will be subjected to freezing temperatures.
The LP cylinder must be disconnected and removed from the
appliance before the appliance can be stored indoors.
Figure 9
LIGHTING INSTRUCTIONS
Warning: If these instructions are not followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
1. Open the tank drawer and find the control panel on the left. Make sure the control knob is in
the "OFF" position. See Figure 10. Open the tank valve all the way.
IGNITER BUTTON
Figure 10
CONTROL KNOB
2. Push in the igniter button. You will hear a slight clicking sound. With the igniter button
pushed in, push and turn the control knob to the "ON" position. The fire should light within a
few seconds. Once the flame is lit, release the igniter button and continue to hold the control
knob in for 10 to 15 seconds. Release the control knob. The control knob should pop back out
and then the fire remain lit. Note: If the fire does not light, turn the knob to the "OFF" position
and wait five (5) minutes before trying again.
3. To turn down the flame, push the control knob in slightly and turn to Medium (medium
flame), or Low (small flame).
4. To shut down the firepit, turn the control knob to the "OFF" position and turn off the tank
valve.
10