Electrical Connection - Infiniton 1040YA1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

without the use of a tool.

ELECTRICAL CONNECTION

The appliance must be fitted correctly to guarantee electrical safety. During fitting and
maintenance operations, the appliance must be unplugged from the electrical grid; fuses must be
switched off or removed.
The electrical connections are made before the appliance is installed in its housing.
Ensure that:
-
the electrical installation has sufficient voltage,
-
the electrical wires are in good condition,
-
the diameter of the wires complies with the installation requirements.
The oven must be connected with a power cable (standardized)with 3 1.5mm
ph+1N+ground) that must be connected to a mono phase 220-240V~ network via a CEI 60083
standardized receptacle 1 ph+1 neutral + ground lead or an all pole cut-off device in accordance
with installation rules.
WARNING
The safety wire (green-yellow) is connected to the appliance's
connected to the earth terminal of the electrical set-up.
You must enable the appliance to be disconnected from the supply network after installation.
Disconnection can be enabled by ensuring that there is an accessible power plug or by
incorporating a switch into the fixed wiring in compliance with the installation rules. The fuse in
your set-up must be 16 amperes. If the power cable is damaged, it should be replaced by the
manufacturer, its after-sales service department or a similarly qualified person to avoid danger.
WARNING
We cannot be held responsible for any accident resulting from non-existent, defective or incorrect
earthing. If the electrical installation in your residence requires any changes in order to hook up
your appliance, call upon a professional electrician.
If the oven malfunctions in any way, unplug the appliance or remove the fuse corresponding to the
sector where the oven is hooked up.