Basic Operation
MUTE/TEST Button:
Silence the UPS On-Battery Alarm: Press and hold this button to
silence the UPS on-battery alarm, a series of short beeps followed by a
brief pause that is activated when the UPS is providing AC power from
battery.
Note: When the battery is nearly depleted, the low battery alarm—a continuous
beep that cannot be silenced—will warn to shut down connected equipment
immediately.
Run a Self-Test: To run a self-test, leave connected equipment on. With
the UPS plugged in and ON, press and hold the button until the UPS
beeps (about 2 seconds) then release.
Self-Test Results: All LEDs will be lit (except the AVR LED) and the UPS
will emit several short beeps as it momentarily switches to battery to test
charge and load capacity. The test will last up to 10 seconds. If the
inverter is overloaded, the "
" LED will stay lit and the UPS will continue
to beep after the test; if this happens, remove some of the load from the
"UPS/Surge" outlets and run the self-test again. If the batteries are weak,
the "
" LED will stay lit and the UPS will continue to beep after the test.
If this happens, let the UPS charge its batteries for 12 hours and repeat
the test. If the condition persists, contact Tripp Lite for service. CAUTION:
Do not unplug the UPS to test its batteries. This will remove safe
electrical grounding and may introduce a damaging surge into
network connections.

Indicator Lights

All Indicator Light descriptions apply when the UPS is plugged into an AC
outlet and turned on.
LINE POWER: This green light will illuminate whenever the UPS is ON
and receiving normal AC line power.
BATTERY POWER: This yellow light will illuminate when the UPS is
providing equipment with battery power.
REPLACE BATTERY: This red light will illuminate continuously after the
UPS runs a self-test to indicate that the battery is weak. If it remains lit
after allowing the UPS to charge for twelve hours and running a second
self-test, contact Tripp Lite for service.
OVERLOAD: This red light will illuminate continuously to indicate that the
UPS is overloaded when the UPS is providing power from battery or after
the UPS runs a self-test. If it lights up, immediately remove some of the
equipment connected to the "UPS/Surge" outlets and run a self-test.
Large overloads may cause the UPS to shut down.
Automatic Voltage Regulation (AVR): This green light will illuminate
when your UPS is automatically correcting high or low AC voltage. The
UPS will also click gently. These are normal, automatic operations of your
UPS, and no action is required.