ABOUT THE CODES
F
– The F code means your unit is empty and needs to be FILLED with water.
CF
– The CF code triggers after 720 hours of use and means it's time to CHECK YOUR FILTER (wick). Unplug your unit and
check your wick. If your wick is still in good shape, simply clear the code by plugging your humidifier back in. If your wick
needs replacing, follow these quick steps:
1.
Remove the wick from the frame by gently squeezing the tabs around the wick frame. Do not discard your frame.
2.
Insert a new 1043 Super Wick® in the frame and snap the frame shut.
3.
Put the wick and frame back into the unit with the MAX FILL label facing the front of the unit.
8
Plug in your unit and press the power button.
9
Set your desired fan level by pressing
the fan speed button. Your Pedestal has
nine fan speeds that are displayed by F1 (the lowest
speed) through F9 (the highest speed).
Note: On higher speeds, the Pedestal puts out a tremendous
amount of humidity, so it's louder on these levels. Most of our
customers liken it to the sound of a box fan. Rest assured there
is nothing wrong with your unit, it's just working very hard to put
out much-needed humidity.
10
Press the humidity control button to set
your humidity level from 25% to 65%. The
humidistat on your cord will read your home's humidity
and turn your fan off when the set level is reached.
When set to 65%, your unit will run continuously.
That's it! Your Pedestal is ready to use.
HOW TO CLEAN YOUR PEDESTAL
Regular cleaning is important for preventing mold,
mildew, and other bacterial growth in your humidifier.
It also keeps your EP9 working its best.
1. Let the unit run until it's empty, then turn it off and
unplug it.
2. Lift the top off the Pedestal, and remove the wick and
wick frame from the base.
3. Throw your wick away if it is time to replace it.
Otherwise, remove it from the wick frame (keep your
frame) and put the wick in a sink while you finish
cleaning your Pedestal.
4. Pour out any remaining water from the base.
5. Fill the base half-full with water and add 1 cup of white
vinegar. Let sit for 20 minutes. To disinfect, replace
the vinegar with 1 teaspoon of bleach. Do not mix
vinegar and bleach.
6. After 20 minutes, empty the base.
7. Dampen a sponge with white vinegar, wipe down
the base, float, and wick frame. Rinse everything
thoroughly. To disinfect, replace the vinegar with
bleach.
8. Wipe everything dry. Put your existing wick (or a new
one) in the wick frame. Then reassemble the unit.
When storing your Pedestal, discard the used wick (keep your
wick frame) and disinfect the unit using the directions above.
Dry the unit thoroughly, and store in a temperature-regulated
area. Do not install a new wick until you are ready to use your
humidifier again.