It is the responsibility of the healthcare provider to ensure patient is educated on the
proper use of the system.
It is the responsibility of the healthcare provider to modify Patient Guidelines provided
with the pump as appropriate for your patients' clinical status and medication
prescribed.
CAUTIONS
Do not use if package is open, damaged or a protector cap is missing.
Single use only. Do not resterilize, refill or reuse.
Reuse of the device could result in the following risks:
• Improper functioning of the device (i.e., inaccurate flow rate)
• Increased risk of infection
• Occlusion of the device (i.e., impedes or stops infusion)
• The pump is sterile and non-pyrogenic.
Product uses Di (2-ethylhexyl) phthalate (DEHP) plasticized PVC:
• DEHP is a commonly used plasticizer in medical devices. There is no conclusive
scientific evidence to date that exposure to DEHP has a harmful effect on humans.
However, the risk and benefit of using medical devices with DEHP for pregnant
women, breastfeeding mothers, infants and children should be evaluated prior to use.
• Certain solutions may be incompatible with the PVC material used in the
administration set. Consult drug package insert and other available sources of
information for a more thorough understanding of possible incompatibility problems.
Do not underfill pump. Underfilling the pump may significantly increase the flow rate.
Do not exceed maximum fill volume. (Table 1)
The fill volume and infusion rate are labeled on the fill port.
Flow rate is unpredictable if it is dialed between rate settings.
Clamp is provided to stop the infusion. Do not remove or break clamp. Do not use
clamp as an intermittent delivery device.
Roll tubing between fingers to promote flow if clamped for extended time.
Avoid contact of cleansing agents (like soap and alcohol)
with the filter because leakage may occur from the air eliminating vent.
Do not tape over filter(s) as this could block the air vent and impede the infusion.
Do not immerse the pump in water. Take care to protect the pump during any activities,
which could cause the pump and filter to get wet, such as showering.
In the event of any leakage from the pump or administration set, close tubing clamp.
Replace pump if necessary.
Do not discard the pump and contact your representative for product return
instructions.
Do not add unvented filter to end of the administration set as this may impede or stop
the flow rate.
Flow rates may vary due to:
Fill volume
Filling the pump less than the labeled volume results in faster flow rate.
Filling the pump greater than the labeled results in slower flow rate.
Viscosity and/or drug concentration.