Descargar Imprimir esta página
Fantech DG Serie Manual De Instalación
Fantech DG Serie Manual De Instalación

Fantech DG Serie Manual De Instalación

Publicidad

Enlaces rápidos

Installation Manual
Item #: 401454
Rev Date: 080113
DG.. CG.. HG.. MGE.. MGS.. Series
Exhaust and/or Supply Grille with Mounting Collar
or RSKC (exhaust only) Type Collar with Backdraft Damper
Step 1
Select the grille mounting point within the area to be ventilated. To ease installation,
locations of framing beams within the walls or joists supporting the ceiling should be
considered. Collar is provided with a perforated hanging strap for attachment directly to a
beam or joist. if the location of the grille does not allow direct attachment, a cross-member
mounted to the framing should be used.
Step 2
Place the mounting collar in the selected location and trace a circle onto the surface. From
the interior side of the room, cut through the surface. Please note: In order to assure a
smoother finish when mounting through a sheetrock or tile type ceiling, it is recommended
that a razor knife be used to make the cut.
Step 3
From within the attic or crawl space, place the mounting collar into the hole until the edge of
the collar is flush with the interior wall or ceiling surface. Attach collar to the support beam
with the 1" wood screws provided. Attach duct work. Please note: If beam or joist exceeds
the height of the collar, allow sufficient space between the collar and the beam to attach the
duct work. Also, when attaching flex duct to the collar/damper combination and an immediate
elbow is necessary, be certain that the elbow is installed with a "soft" bend to allow damper
to operate preperly.
Step 4
Snap the grille into the mounting collar. Grille
should be pushed tightly into place for an
airtight fit - Grille models DG, CG, HG, MGE
and MGS are designed for balancing airflow
(more open = more air, more closed = less
air).
United States • 1.800.747.1762 • www.fantech.net
Canada • 1.800.565.3548 • www.fantech.ca
fantech
Fantech reserves the right to make technical changes.
For updated documentation please refer to www.fantech.net

Publicidad

loading

Resumen de contenidos para Fantech DG Serie

  • Página 1 MGS are designed for balancing airflow (more open = more air, more closed = less air). United States • 1.800.747.1762 • www.fantech.net Canada • 1.800.565.3548 • www.fantech.ca fantech Fantech reserves the right to make technical changes. For updated documentation please refer to www.fantech.net...
  • Página 2 Manuel d’installation Installer la grille DG, CG, HG MGE et MGS avec le collier de fixation ou le collier RSKC (évacuation seulement) avec le régulateur de décharge Étape 1: Sélectionner le lieu d’installation de la grille au sein de l’espace être ventilé. Pour faciliter l’installation, on devrait tenir compte de l’emplacement des colombages dans les murs ou encore des solives supportant le plafond.

Este manual también es adecuado para:

Cg serieHg serieMge serieMgs serie