18. Fix the lower section of the chimney with two screws.
19. Fix them above with 2 screws (19a) to the G flues
support bracket (19b).
Remount the carbon filter frame and the fat/s filter/s and check
the perfect functioning of the hood.
Installing the panel
(number and form of the panels can vary on the basis of the
model)
The panel is supplied dismounted.
Hook the panel onto the pins of the hood and fix with the
supplied latch S (the number varies on the basis of the model
- safety-fixing compulsory!).
Rotate the panels to cover the suction area and hook to the
pins, pressing with decision.
Check that the panel is blocked in position. Fig. 6
Description of the hood
Fig. 1
1. Control panel
2. Grease filter
3. Grease filter release handle
4. Halogen lamp
5. Vapour catcher
6. Telescopic chimney
7. Air outlet (used for filter version only)
8. Panel
Operation
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Control panel
To select the functions of the hood just touch the commands.
Light key ON/OFF
Intensive speed selection key (suction
power) - duration 5 minutes - press again to
return to previous setting.
High-speed selection key (suction power).
Medium-speed selection key (suction power)
- when flashing it indicates the need to wash or
replace the carbon filter. This signal is normally
deactivated. Press keys 1 and 2 at the same
time to activate it. At first only key 1 will flash
and then both keys 1 and 2 to indicate
activation. Repeat the operation to deactivate
the signal. At first keys 1 and 2 will flash and
then only key 1 to indicate deactivation.
Low-speed selection key (suction power) –
when flashing it indicates the need to wash the
fats filter.
Motor key OFF (stand by) – excludes the
electronics – reset wash/replace filters signals.
MOTOR OFF
Press briefly to switch the motor off.
RESET FILTERS SIGNALS
After having carried out maintenance of the
filters, press the key for 3 seconds. Flashing led
1 (fats filter) or 2 (carbon filter) will stop
flashing.
EXCLUDING THE ELECTRONICS
Press the key for 3 seconds. The hood
command electronics will be excluded.
This function can be useful during the product
cleaning operations.
Just repeat the operation to reinsert the
electronics.
If the hood fails to operate correctly, briefly disconnect it from
the mains power supply for almost 5 sec. by pulling out the
plug. Then plug it in again and try once more before
contacting the Technical Assistance Service.
Maintenance
ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING:
Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire
risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.