(Fig. 12, A).
5)
Pour solvent or water into the container. Screw the container back on.
Do not use flammable materials for cleaning purposes.
6)
Assemble the gun again (Fig. 5).
7)
Turn on the machine and spray the solvent or water into a container or a cloth.
8)
Repeat the above procedure until the solvent or water emerging from the nozzle is
clear.
9)
Turn off the machine and divide the spray gun.
10)
Screw of the container and empty it. Pull out the suction tub with container seal.
CAUTION! Never clean seals, diaphragm and nozzle or air holes of the spray gun
with metal objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited
extent. Do not immerse in solvent, only wipe.
11)
Pull the ventilating hose (Fig.13, A) at the top from the gun body. Screw off the valve
cover (B). Remove the diaphragm (C). Clean all the parts carefully.
12)
Unscrew the union nut and remove the air cap and nozzle. Clean the air cap, nozzle
seal and nozzle with a brush and solvent or water (Fig. 14).
13)
Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
14)
Assemble the parts again (see "Assembly").
Assembly
The unit may only be operated with an integer diaphragm (Fig. 13 ,C).
Place the diaphragm with the pin facing upwards on the bottom section of the valve.
Also see the marking on the gun body. Place on the valve cover and screw it closed. Place
the ventilating hose on the valve cover and on the nipple at the gun body.
Slide the nozzle seal (Fig. 15, A) with the groove (slot) facing forwards into the nozzle (Fig. 15, B).
Put the nozzle onto the gun body and find the correct position by turning it. Put the air
cap onto the nozzle and tighten it using the union nut.
Place the container seal from below on the suction tube and slide it over the collar, while
turning the container seal slightly. Insert the suction tube with container seal in the gun
body.
Maintenance
Replace the air filters depending on soiling. Unplug the power plug. Open the cover of
the air filter compartment (Fig. 16, A). Replace both air filters (Fig. 16, B). Close the cover
of the air filter compartment.
WARNING! Never operate the machine without the air filter; dirt could be sucked in
and interfere with the function of the machine.
In order to mount the gun more easily apply lubricating grease (enclosed) liberally
to the O-ring at the spray attachment (Fig. 14, A).
40