Plaster
Guards
4. Finish the Wall
NOTE: To ensure proper fit and appearance, do not oversize the
spout and handle shank holes.
Complete the finished wall with two 1-7/8" (4.8 cm) diameter
holes for the spout and handle shanks. Space the hole centers 4"
(10.2 cm) apart.
Remove and discard the plaster guards when the finished wall is
complete.
5. Adjust the Water Temperature
NOTE: Prior to adjustment, make sure the handle is in the
maximum hot position.
Remove the handle, cap and escutcheon. Turn the water to the
maximum temperature by pushing the valve stem down and
turning counterclockwise.
Mark the current position of the temperature stop tab (top edge)
on the mounting nut with a marker or pencil. Lift both the
indexer and disc just enough to clear the splines and allow
rotation.
NOTE: Each spline notch represents an average 9.5° F (5.3° C)
temperature change.
Kohler Co.
Mounting
Nut
Stop Tab
Valve Stem
Splines
Disc
Indexer