Operation And Maintenance; Sludge Removal; Cleaning The Anaerobix Filter; Aeration And Ventilation - Graf ANAEROBIX 107883 Instruccion Para La Instalacion

Tabla de contenido

Publicidad

Operation of the system may be subject to a permit. Please enquire in advance from the relevant public
authority.
5.1

Sludge removal

Sludge removal is to be carried out at the latest when the sludge level has risen to 70 %.
5.2

Cleaning the ANAEROBIX FILTER

The ANAEROBIX filter should be checked regularly for blockages or backups. If necessary, the bags with
the carrier material are to be removed from the filter and cleaned. We recommend cleaning the carrier
material with a water hosepipe.
In accordance with DIN 4261-1 all chambers / tanks are to be aerated. If necessary, additional ventilation
lines or ventilation openings are to be arranged. The ventilation lines are to be positioned in such a way
that natural ventilation is possible (flue effect).
Ventilation with free discharge
Otto Graf GmbH – Carl-Zeiss-Str. 2-6 – DE-79331 Teningen – Tel.: +49 7641 589-0 – Fax: +49 7641 589-50
GRAF Distribution S.A.R.L – 45, route d´Ernolsheim – FR-67120 Dachstein Gare – Tél.:+33 388 49-7310 – Fax: +33 388 49-3280
GRAF Iberica Tecnología del Plástico S.L. – Marquès Caldes de Montbui, 114 – ES-17003 Girona – Tel.: +34 972 913767 – Fax: +34 972 913766
GRAF UK Ltd – Target House – Thorpe Way Ind. Estate – Banbury – Oxfordshire – UK-OX16 4SP – Tel.: +44 1608 661-500 – Fax: +44 1295 211333
mail@graf.info
www.graf.info
5.

Operation and Maintenance

6.

Aeration and ventilation

16 / 32
Ventilation with seepage or discharge not free
2017-05