INSTALLATION INSTRUCTIONS
(Translation from original)
SP-DIO
Extension module of the modular safety control
samos®PRO COMPACT
BA001033 - 09/2017 (Rev. C)
1
About this document
1.1 Documents for the samos®PRO COMPACT
System
This assembly instruction describes the assembly of the unsafe
extension module SP-DIO to the safety control samos®PRO COM-
PACT.
The assembly of other samos®PRO modules is described in a
separate instruction.
Mounting method, configuration and commissioning of the safety
control samos®PRO COMPACT are described in the following
operating instructions:
Document
Title
Manual
samos®PRO COMPACT hardware
Manual
samos®PLAN6 software
Manual
samos®PRO COMPACT gateways
Furthermore, specialized technical knowledge that is not provided in
this document is required when installing safety equipment.
1.2 Function of this document
This assembly instruction guides the technical personnel of the
machine manufacturer or machine operator in the safe installation of
the expansion modules of the modular safety control samos®PRO
COMPACT.
These assembly instructions do not provide instructions for operat-
ing the machine in which the safety control is or will be integrated.
The operating instructions of the machine contains information on
this subject.
2
Safety
This section is intended to support your safety and the safety of the
system users.
Please read this section carefully before you start the assembly.
2.1 Qualified persons
The modular safety control samos®PRO COMPACT must only be
assembled by capable persons.
Qualified persons are those who...
have suitable technical training and
have been trained by the machine operator in the operation and
applicable safety guidelines and
have access to the samos®PRO COMPACT operating instructions
and have read said instructions and have duly noted these and
have access to the operating instructions for the safety devices
connected to the safety control and have read them and duly
noted them.
2.2 Applications
The modular safety control samos®PRO COMPACT is a programma-
ble control system for safety applications. It can be used
as per EN 61508 up to SIL 3
as per EN 62061 up to SIL CL 3
as per EN ISO 13849-1: 2015 up to Performance Level (PL) e
as per EN ISO 13849-1 up to Category 4
The level of safety actually achieved depends on the external wiring,
the implementation of the wiring, the parameterization, the selection
of the command encoder, and the modules and their arrangement
on the machine.
Opto-electronic and tactile safety sensors (e. g. light curtains, laser
scanners, safety switches, sensors, emergency stop switches) are
connected and logically linked with the modular safety control.
Wieland Electric GmbH
Brennerstr. 10-14
D-96052 Bamberg
www.wieland-electric.com
Printed in Germany
All rights reserved
EN
The corresponding actuators on the machine or systems can be
securely switched off via the safety-related outputs of the safety
control.
2.3 Intended use
The modular safety control samosPRO must only be used within
specific operating limits (voltage, temperature etc., see Section 5
"Technical data). It must only be used by expert personnel and only
on the machine where it has been installed and initially commis-
sioned by a capable person in accordance with the samos®PRO
COMPACT operating instructions.
In the event of any other use or any changes to the device – includ-
ing within the scope of installation – this shall nullify any sort of
warranty claim with respect to Wieland Electric GmbH.
Number
BA000966
2.4 General safety information and protective
BA000968
measures
BA000970
CAUTION
CAUTION
Observe during the installation, mounting method, instead of:
Installation and application of the safety control system sa-
mos®PRO COMPACT the standards and guidelines valid in your
country.
The national/international legal regulations apply to the installation
and use of the samos®PRO COMPACT safety control as well as for
the commissioning and recurring technical testing, particularly the
following
– EMC Directive 2014/30/EU
– Machinery Directive 2006/42/EG
– Work Equipment Directive 2009/104/EC
– Low-Voltage Directive 2014/35/EU
– Elevators Directive 2014/33/EU
– The accident prevention regulations/safety rules
Manufacturers and operators of a machine on which a sa-
mos®PRO COMPACT safety control is being used are responsible
for coordinating with the proper authorities with regard to appli-
cable safety guidelines/rules and complying with these.
The information in these assembly instructions must be followed
without fail.
The tests must be conducted by qualified persons or by those who
are personally authorized and commissioned to do so and must
always be fully documented at all times by a third-party.
The external power supply of the devices must be able to bridge a
short-term power outage of 20 ms in accordance with EN 60204.
Appropriate PELV and SELV compatible power supply units are
available as accessories from Wieland Electric.
The modules of the samos®PRO COMPACT system correspond to
class A, Group 1, in accordance with EN 55011.
– Group 1 includes all ISM devices in which intentionally generat-
ed and/or used wired HF power, which is required for the inter-
nal function of the device itself, occurs.
Note the safety information and protective
measures!
Note the following points in order to ensure intend-
ed use of the samos®PRO COMPACT safety control.
Use of the inputs/outputs IY5...iY8
When using the combination connection as an
input, the signal input voltage at IY5...IY8 must
never be greater than the supply voltage at A1/A2.
5