13F3, 13F3.B - 13F5, 13F5.B
Manual configuration parameters of the electronic unit
Perform the following procedure with the panels powered and after assigning the entrance panel ID code. This procedure applies to all panels, Master and Slave.
During programming, the entrance panel is in engaged status and cannot be used for normal system operation. There are 8 buttons and 6 green LEDs in total on the
electronic unit.
The 6 (screen printed) buttons at the bottom are used for programming, along with the 4 green LEDs at the bottom. Which function as indicators for the variation of standard
parameters. For convenience, we call the 4 green LEDs DL3, DL4, DL5, DL6 (see figure 5). During programming the 6 buttons assume the functions:
PREC. PREV = return to the previous sequence
SUCC. NEXT = move to the next sequence
OK = to move from the sequence menu to parameter modification
START SI/YES = function depends on the parameter type
STOP NO = function depends on the parameter type
FINE END = used to exit parameter modification or to exit programming (depends whether you are in parameter modification or the "sequence" phase).
Electronic unit parameter configuration procedure using the keys:
- Press and release the RST (reset) button.
- Press and hold the PRG button and the top right-hand button simultaneously.
- After 2 s, the electronic unit will emit a sharp tone.
- Enter the Password by pressing the buttons 6-5-4-3-2-1 (Default) in sequence.
If the password is correct, the LEDs will switch off, otherwise the electronic unit will emit a low tone to indicate its exit from programming mode.
- Use the 6 screen printed buttons to adjust the parameter values. The LEDs indicate the current function, the PREV. and NEXT buttons select the parameter, the OK button
enters parameter modification mode, the END button exits parameter modification mode.
Modification mode is also exited due to a timeout (30 s), indicated by the emission of a low tone. The timeout period is extended by 30 s every time a button is pressed.
For rapid exit from the programming phases, press the END button at any time.
6
fig.5
4
START
SI / YES
DL3
5
STOP
NO
DL5
6
FINE
END
3
1
PREC.
PREV
DL4
2
SUCC.
NEXT
DL6
3
OK
EN