Maintenance and Cleaning Instruction
IMPORTANT: The dryer may collect lint and debris that is naturally present in the air. Excessive
build up of lint and debris can damage the motor and heating element. The dryer should be
cleaned on a routine schedule to maintain the dryer in good operating condition With light
to moderate wash room traffic, cleaning once a year is recommended. If wash room traffic is
high, cleaning every 6 months is recommended.
To clean the hand dryer:
1. Disconnect the power source.
2. Use the security hex key supplied to turn the cover mounting screws
cover from the dryer.
3. Use a soft-medium bristle paint brush to clean lint, dust and debris from the air intake slots, and
the motor's exterior.
4. After cleaning, reassemble the dryer cover using the security hex key supplied to turn the cover
mounting screws
HEPA Filter Replacement
High efficiency particulate absorbtion )HEPA(
filters remove a minimum of 99.97% of
contaminants 0.3 microns in size or larger.
The service life of a HEPA filter depends on the
environment in which the dryer is installed and
frequency of use. High traffic washrooms or
high usage will require more frequent inspection
and replacement of the HEPA filter. When visual
inspection of the HEPA filter shows excessive
buildup of lint, dust and debris, the filter should
be replaced.
Examining and changing a HEPA filter regularly
keeps hand dryers working efficiently. Operating
a hand dryer with an excessively dirty or clogged
filter can damage your machine.
The HEPA filter cannot be cleaned and re-used.
Do not clean the HEPA filter or allow it to come
into contact with water.
To inspect or replace the HEPA filter:
1. Disconnect the power source.
2. Use the security hex key supplied to turn
the cover mounting screws
remove the cover from the dryer.
3. Removing and replacing the HEPA filter
is easily done by sliding the filter in its
mounting track on the motor cap.
4. After replacing the HEPA filter, reassemble
the dryer cover using the security hex key
supplied to turn the cover mounting screws
counter-clockwise
snug. Do not over tighten.
5. Reconnect the power source.
counter-clockwise
clockwise
and tight until
and tight until snug. Do not over tighten.
HEPA Filter
Optional Accessory
Coarse Filter
to
6
clockwise
to remove the
Black Foam
Seal
Figure 3