9.15 Interrupt assignment of the slot connectors on the bus board
Bus board 3x PCI, 3x PCIe x4, 5x PCIe x16
Affected order numbers: 6AG4114-2xxx1-xxxx and 6AG4114-2xxx3-xxxx
Table 2
Slot
1
2
Type
PCIe
PCIe
4x
4x
PCH
PCH
4 lanes*
4 lanes*
switched
switched
IRQ
0x0A
0x05
* Number of active PCIe lanes in the direct connector of the slot
** For details, see Table 3
Table 3
Plug-in scenarios
Slot 6
Free
Free
Free
Occupied
Occupied
Occupied
Occupied
278
3
4
PCIe
PCIe
4x
x16
PCH
PCH
4 lanes*
4 lanes*
4 lanes*
switched
switched
switched
0x0B
0x0A
Slot 7
Slot 8
Free
Occupied
Occupied
Free
Occupied
Occupied
Free
Free
Free
Occupied
Occupied
Free
Occupied
Occupied
5
6**
7**
PCIe
PCIe
PCIe
x16
x16
x16
PCH
CPU
CPU
4 lanes*
4 lanes*
0x0A
See table 3
Slot 6
/
/
/
0x0A
0x0A
0x0B
0x0B
Instrucciones de servicio, 03/2018, A5E32997461-AC
8**
9
10
PCIe
x16
CPU
PCI
PCI
8 lanes*
0x0B
0x0B
IRQ
Slot 7
/
0x0A
0x0A
/
/
0x0A
0x0A
SIMATIC IPC847D
11
PCI
0x0B
Slot 8
0x05
/
0x05
/
0x05
/
0x05