3�
Install washer in female end
of adapter, and then connect
adapter to range gas inlet pipe
via compression fitting and
tighten�
NOTE: Washer must be used to
create a leak proof seal�
How to connect gas line from gas pressure regulator to gas supply (Refer to Figure 13�)
1�
Apply pipe-joint compound made for use with NG (natural gas) to the tapered (NPT) threads of both
adapters supplied with gas line kit�
2�
Attach one adapter to the gas pressure regulator and the other to the gas shut-off valve and tighten both�
Pressure Regulator
(provided)
NOTE: DO NOT rotate the gas
pressure regulator�
3�
Attach the flexible gas
supply line to adapters, one
adapter at each end�
IMPORTANT: All connections
must be wrenched tightened
(requires two 10" adjustable
wrenches)�
CAUTION: DO NOT over-tighten
the connections to the gas
pressure regulator� Overtightening
may crack the regulator creating
a gas leak�
How to Complete Gas Connection
1�
Open the manual shut-off valve in the gas supply line�
•
The valve is open when the handle is parallel to the gas pipe�
2�
Test all connections by brushing on an approved noncorrosive leak-detection solution�
•
Bubbles indicates a leak� Correct any leaks found�
Adapter
(provided)
13
Gas Line from Range
Washer (provided)
Adapter (provided)
Gas Pressure Regulator (provided)
Adapter
Gas Shut-Off
(provided)
Valve
Gas
Shut-Off
Valve
Adapter (provided)
Gas Pressure Regulator
Gas Supply Line
Figure 12
Figure 13
Figure 14
Adapter
(from Gas
Supply
Line Kit)
Adapter (from
Gas Supply
Line Kit)