iii
ULTRATEMP
MENU TREE QUICK START GUIDE
®
1. Push the ON/OFF button to turn the unit on, the green "ON" light should be lit.
2. Select either Pool or Spa mode. The default is Pool mode.
3. Adjust the temperature to the desired setting by pushing either the UP arrow or DOWN arrow.
4. Allow 5 minutes for compressor restart delay.
See pages 17-22 for details on the Operator and Service menu screens on the control panel.
OPERATOR
MENU TREE
POOL
IDLE/HEAT/COOL
SET=__
ACT=__
SPA
IDLE/HEAT/COOL
SET=__
ACT=__
HEAT / COOL / AUTO
SET TO - H/C/A
HEAT PUMP RUNTIME
REMAINING = NONE
REMOTE MODE
OFF/RELAY/RS-485
AUTOSET
HEAT/COOL/AUTO
OVERRIDE IS ON/OFF
EXTEND
HEAT/COOL/AUTO
OVERRIDE IS ON/OFF
RESTART / PUMP START /
SENSING WATER TEMP
DELAYS
SUCTION TEMP
ACTUAL = ___
ALARM STATUS
HEAT/COOL/AUTO MODE
POOL/SPA
*
Menu appears only if Heat and Cool mode is enabled
at the factory.
**
Menu appears only if AutoSet or Extend is enabled in the
Service menu.
***
Menu appears only if a delay is active.
****
Menu appears only if Defrost is enabled in the Service menu.
ULTRATEMP
Heat Pump Installation and User' s Guide
®
*
**
**
***
****
SERVICE
MENU TREE
LANGUAGE - IDIOMA - LANGUE
ENGLISH / ESPANOL / FRANCAIS
SOFTWARE VERSION
REV. ____
INTELL ADDRESS
ADDRESS = 1-16
PUMP START TIME
TIME = 1 - 4 HRS
PUMP START DELAY
TIME = 0 - 5 MINS
TEMPERATURE SCALE
FAHRENHEIT / CELSIUS
WATER TEMP OFFSET
OFFSET = -2 TO +2
DEFROST
ENABLE / DISABLE
AUTOSET
ENABLE / DISABLE
EXTEND
ENABLE / DISABLE
WF HP LP PL SP
1
1
1
0
0
FAN COMP PMP REV
1
1
1
0
TEMP. RECORD
HOUR # ___ ___°F
RUN TIMES/COUNTS
PRESS POOL/SPA
TO EXIT SETUP
†
INPUT STATUS
WF = WATER FLOW SWITCH
HP = HIGH REFRIGERANT PRESSURE SWITCH
LP - LOW REFRIGERANT PRESSURE SWITCH
PL - POOL REMOTE
SP - SPA REMOTE
**
†
THE NUMBER ONE (1) IS
DISPLAYED WHEN THE
ASSOCIATED INPUT/
OUTPUT IS ON AND ZERO
††
(0) IS DISPLAYED WHEN
INPUT/OUTPUT IS OFF.
††
OUTPUT STATUS
FAN - FAN
COMP - COMPRESSOR
PMP - FILTER PUMP
REV - REVERSING VALVE