Connector; Pin Configuration For Heat Pump Control Board To Intellitouch; Connecting Intellitouch Or Easytouch To The Heat Pump - Pentair ULTRATEMP 70 Guía De Instalación Y Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Pin Configuration for the Heat Pump Control Board to IntelliTouch
1. Heat Pump Control Board: Connect pin 2 (green) to
IntelliTouch screw terminal pin 2 (green).
2. Heat Pump Control Board: Connect pin 3 (yellow) to
IntelliTouch screw terminal pin 3 (yellow)
IntelliTouch Screw Terminal
COMMUNICATION PORT
COM PORT (J7 / J8)
Pin Configuration for connecting IntelliFlo
1
BLK
Strip back the cable conductors 1/4". Insert the two wires into either of the
2
GRN
COM PORTS (J7 and J8) screw terminals. Secure the wires with the screws.
YEL
3
Note: Multiple wires may be inserted into a single screw terminal.
RED
A communication expansion module with 3 extra COM ports and 4 IntelliFlo
4
pump ports is available (P/N 520818).
• IntelliFlo: Connect pin 6 (green) to IntelliTouch screw terminal pin 2 (green)
• IntelliFlo: Connect pin 7 (yellow) to IntelliTouch screw terminal pin 3 (yellow)
INDOOR CONTROL
(AND/OR)
iS10 SPA-SIDE REMOTE.
(AND/OR)
Connecting the IntelliTouch or EasyTouch
to Heat Pump
1. Turn off the power to both the remote pool/spa control
system and the UltraTemp
2. Remove the front left panel of the heat pump cabinet,
(you do not need to remove the star-head screw at
the top left corner).
3. Remove the electrical service panel to the heat pump.
Remove the 4 bezel retaining screws from above
the electrical compartment and rotate the bezel
downward. This will allow you to access the Remote
terminals on the back of the heat pump control board
for the remote control installation.
4. Run the wires from the pool/spa remote control
system into the upper electrical compartment.
5. Connect the wiring from the IntelliTouch Personality
Board COM PORT to the RS-485 IntelliTouch
connection (J8) on the heat pump control Board.
Connect the green wire to J8 pin 2 and yellow wire
to J8 pin 3. Do NOT use pin 1 (red) or pin 4 (black)
wires. The connections are shown in the image above.
6. Rotate the bezel back upwards into position and
reinstall the 4 retaining screws.
®
to IntelliTouch
®
:
PIN 2
(Green)
RF TRANSCEIVER
SWITCHES
Heat Pump.
®
IMPORTANT — Do NOT use pin 1 (black) or pin
4 (red) on the AutoSet board or the IntelliTouch
mother board.
J8
RS-485
Heat Pump Control Board
INTELLITOUCH
CONNECTION
PIN 3
(Yellow)
INPUT
DEF
WTR
3 - WIRE
TEMP
TEMP
REMOTE
J9
J5
J4
TERM.
THERM1
THERM2
SPA
COM
7. Replace the electrical service panel.
8. Replace the front left panel.
9. Restore power to the heat pump and the pool/spa
remote control system.
10. Press the MENU SELECT button to scroll to the
Remote Mode screen. Toggle the selection by
pressing one of the arrows until the screen displays
"RS-485."
11. Once the heat pump has been correctly configured, a
"heartbeat" indicator will appear on the main screen
each time a message is received from the automation
system.
POOL HEATING F
SET= N/A ACT= 74
Note: If the system is put into Service Mode at the
automation control panel the heat pump will neither
heat nor cool, although it will remain powered on.
ULTRATEMP
Control System
®
IntelliTouch
COM PORT (J7/J8)
screw terminal
IntelliTouch
AutoSet Board
screw terminal
(4-wire cable)

connector

2 (GRN)
GREEN (PIN 2)
3 (YEL)
YELLOW (PIN 3)
PIN CONFIGURATION
Heat Pump Control Board
OUTPUTS
J3
PWR
J7
24 VAC
POOL
*
Heartbeat
Indicator
Heat Pump Installation and User' s Guide
®