20
Timers And Delays
1. Water Sensing Timer
One (1) minute timer to allow water from the pool to
reach the UltraTemp
temperature. This timer initiates when water first begins
to run from stopped or low water flow conditions or
when the heat pump is turned ON. Countdown time
is in Minutes and Seconds.
SENSING WATER TEMP
REMAINING = 1:00
2. Restart Delay Timer
Five (5) minute timer is a protection feature for the
heat pump's compressor. This extends the life of the
compressor by not allowing it to cycle on and off
rapidly, (i.e. adjusting set point up and down around
actual temperature). Countdown time is in minutes
and seconds.
RESTART DELAY
REMAINING = 5:00
3. Defrost Delay Timer
Fifteen (15) minute timer where the Heat pump is
in Defrost operation. Countdown time is in minutes
and seconds. Refer to page 22 for more details on
the defrost cycle.
DEFROST DELAY
REMAINING = 15:00
4. Pump Start Delay
One to four (1-4) hour timer used in conjunction with
the AutoSet feature. Counts down the time until the
control board will energize the internal contactor in the
heat pump. Countdown time is in hours and minutes.
See AutoSet section for more details.
PUMP START DELAY
REMAINING 4:00
5. Heat Pump Runtime Timer
This feature is an adjustable timer to allow the heat
pump to run (green light ON) for a predetermined
amount of time and then turn OFF (green light OFF).
During the selected time frame the green light is ON
and the heat pump will function in the normal mode
of operation and/or the operator can change set
points, functions, etc. The heat pump's green light
will turn OFF and the heat pump will stay OFF when
time expires.
HEAT PUMP RUNTIME
REMAINING = NONE
ULTRATEMP
Heat Pump Installation and User' s Guide
®
Heat Pump before acquiring
®
Control Panel Alarm Messages
HIGH WATER
Water temperature is above
TEMP
107°F [41.7°C].
LOW WATER
Water temperature is below
TEMP
40°F [4.4°C].
LOW WATER
The pressure switch sensing
FLOW
water flow is open.
Pool and Spa relay remote
REMOTE
inputs are simultaneously
POOL/SPA
energized.
WATER THERM
Water temperature thermistor
SHORT
circuit shorted.
WATER THERM
Water temperature thermistor
OPEN
circuit open.
SUCTION TH
Defrost thermistor circuit
SHORT
shorted
SUCTION TH
Defrost thermistor circuit
OPEN
open.
LOW AMBIENT
Air temperature is too low for
TEMP
heat pump operation.
The 24 VAC supply voltage to
BROWNOUT
the control board is low.
Refrigerant high pressure
HIGH REFRIG
switch is open.
Refrigerant low pressure
LOW REFRIG
switch is open.
Control board has not
SERIAL COMM
received a message from the
LOST
automation controller for two
(2) minutes.
Indicates that five (5) faults
have occurred in one (1) hour.
This fault will automatically
FIVE ALARMS
reset in one (1) hour or can
be manually reset by pressing
the ON/OFF button.