Teka GFG2 Manual De Usuario página 15

Ocultar thumbs Ver también para GFG2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
provides full disconnection under overvoltage category III
conditions, in accordance to the wiring rules.
 If a plug is used for the electric connection, then it must be
accessible after installation.
 The air must not be discharged into a flue that is used for
exhausting fumes from appliances burning gas or other fuels
(not applicable to appliances that only discharge the air back into
the room).
 The lower part of the extractor must be located at a minimum
height of 60 cm above the hob for electric cookers and 65 cm for
gas cookers. If the instructions of a gas cooker indicate a greater
distance these must be observed.
 Before installing the extractor consult the local rules and
regulations in force with respect to the discharge of air and
fumes.
 When the extractor is working at the same time as other non-
electrical cooking equipment, the outlet air pressure must not
exceed 4 Pa (4x10-5 bar).
 Before connecting the extractor to the mains, check that both the
voltage and the frequency conform to that shown on the
characteristics label located inside the extractor.
 To achieve optimum performance the length of the outlet hose
should not exceed 4 meters, or include more than two 90º
angles (elbows).
 Although venting to the outside is recommended, activated
carbon filter may be used to allow the gas to be returned to the
kitchen through the outlet pipe.
 NOTE: For more Installation information, refer to the end of this
user manual.
Cleaning
 There is a fire risk if cleaning is not carried out in accordance
with the instructions.
15
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido