Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.
BUILT TO LAST
Description
Portable oilless air compressors are for
home and workshop use. All models
are equipped with regulators, needle
and ball bearings and 1725 RPM, 60 Hz
motors with automatic overload
protection. Cleaning or replacement of
the inlet filter on all models and
draining moisture from the air receivers
are required maintenance.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service.
© 2011 Campbell Hausfeld
Portable Air
Compressors
General Safety
Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up a
high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.
All electrical work
should be done by a
qualified (licensed or certified) electrician. On
a properly wired circuit, the black wires
supply a voltage potential even when the
unit is off.
1. Read instruction manuals for each
component carefully, before
attempting to assemble,
disassemble or operate your
particular system.
2. Do not exceed pressure rating of
any component in system.
3. Protect material lines and air lines
from damage or puncture. Keep
hose and power cable away from
sharp objects, chemical spills, oil,
solvents, and wet floors.
4. Never point a spray gun at oneself
or any other person. Accidental
discharge may result in serious
injury.
5. Check hoses for weak or worn
condition, before each use, making
certain all connections are secure;
do not use if deficiency is found.
Notify an authorized service facility
for examination or repair.
1
WL5000 Series Contractor Models
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
"as is" to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment. This
additional equipment is
necessary to properly filter and
purify the air to meet minimal
specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of
breathing air application and
proper in-line safety and alarm
equipment is not simultaneously
used, existing warranties shall be
voided, and Campbell Hausfeld
disclaims any liability whatsoever
for any loss, personal injury or
damage.
6. Release all pressures within system
slowly; dust and debris may be
harmful.
system before servicing air compressor!
(Turn pressure regulator knob fully
clockwise after shutting off compressor.)
Disconnect power
and depressurize
IN204107AV 2/11

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Campbell Hausfeld WL5000 Serie

  • Página 1 MAY result in minor or moderate injury. used, existing warranties shall be sharp objects, chemical spills, oil, Notice indicates voided, and Campbell Hausfeld solvents, and wet floors. important disclaims any liability whatsoever information, that if not followed, may 4.
  • Página 2 Portable Air Compressors 21. Use a respirator when spraying. 4. Thread outlet pressure gauge into the General Safety 22. NEVER reset safety valve or pressure small port on the regulator. Hand (Continued) switch. Keep safety valve free from tighten with face of outlet pressure paint and other accumulations.
  • Página 3 WL5000 Series Contractor Models ✽ Wire and Terminal Guide Installation (Cont.) Wire Color Terminal a. No other electrical appliances or lights Power cord White Line are connected to the same branch Motor cord White Load circuit. Power cord Black Line Motor cord Black Load...
  • Página 4 Portable Air Compressors 6. Turn regulator knob counterclockwise REGULATOR kNOb Operation (Cont.) to shut off air and turn switch to OFF 1. This knob controls air pressure to an air position. close cock tightly before operating operated tool, or paint spray gun. compressor.
  • Página 5 A. Provide dated proof of purchase and maintenance records. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service Center. Freight costs, if any, must be borne by the purchaser. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
  • Página 6: Troubleshooting Chart

    Portable Air Compressors Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. Loss of power or overheating 1. Check for proper use of extension cord (see EXTENSION CORDS, page 3) 2. No electrical power 2. Plugged in? Check fuse/breaker or motor overload 3.
  • Página 7: Généralités Sur La Sécurité

    7. Suivre toutes les codes locaux produit en service. 5. Vérifier les tuyaux pour rechercher d’électicité et de sécurité, ainsi que tout signe de faiblesse ou d’usure le National Electrical Code (NEC) et IN204107AV 2/11 © 2011 Campbell Hausfeld 7 Fr...
  • Página 8 Compresseurs D’Air Portatifs étincelle peut précipiter l’allumage. Généralités Sur La Circ. d’air Ne pas fumer pendant la pulvérisation Attacher le tuyau Sécurité (Suite) de la peinture, d’insecticides ou autres produits inflammables. le Occupational Safety and Health 21. Utiliser un respirateur pendant la Act (OSHA).
  • Página 9 Modèles Pour Entrepreneurs Série WL5000 ✽ Guide de Fils et bornes Installation (Suite) Couleur borne Chaud REMARQUE: Les modèles de 120 volts, Cordon d’alimentation Blanc Ligne 10 et 13 ampères peuvent fonctionner Cordon du moteur Blanc Charge sur un circuit de 115 volts, 15 ampères Cordon d’alimentation Noir Ligne sous les conditions suivants:...
  • Página 10 Compresseurs D’Air Portatifs 2. Assurer que le manomètre est à ZERO Fonctionnement Régulateur Manostat (Suite) avant de changer les outils pneumatiques ou avant de Soupape débrancher le tuyau. Sûreté MANOMèTRE DU RÉSERVOIR Ouvre Ferme Manomètre Le manomètre indique la pression dans De Réservoir Manomètre Brancher...
  • Página 11 RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Página 12: Guide De Dépannage

    Compresseurs D’Air Portatifs Guide De Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Compresseur ne 1. Perte de puissance ou surchauffage 1. Vérifier l’usage correct des cordons prolongateurs fonctionne pas (voir CORDONS PROLONGATEURS, page 3) 2. Manque de puissance électrique 2. Modèle branché? Vérifier le fusible/disjoncteur ou surcharge du moteur 3.
  • Página 13: Compresores De Aire Portátiles

    WL5000 Serie de modelos para contratistas Manual de instrucciones y lista de repuestos Lea con cuidado antes de tratar de armar, instalar, manejar o darle servicio al producto descrito en este manual. Protéjase a Ud. y a los demas observando todas las reglas de seguridad.
  • Página 14: Ensamblaje

    Compresores de Aire Portátiles envases de metal aprobados para este MULTIPLE Generales de Seguridad tipo de desperdicios. Ensamble el regulador, el manómetro (Continuación) 17. Nunca alamcene líquidos inflamables de salida y el niple (en empaque o gases cerca del compresor. separado) de la siguiente manera: 6.
  • Página 15: Wl5000 Serie De Modelos Para Contratistas

    WL5000 Serie de modelos para contratistas ✽ Guía de cables y terminales Instalación Cable Color Terminal Con tensión 2. Utilice el compresor en un área bien Cordón eléctrico Blanco Línea ventilada para que éste se pueda Cordón del motor Blanco Tensión...
  • Página 16: Funcionamiento

    Compresores de Aire Portátiles Cerciórese de cerrarla bien antes de 6. Gire la perilla del regulador en sentido Instalación (Continuación) utilizar el compresor. Ésto evita que el contrario a las agujas del reloj para tanque se oxide o la acumulación de trancar la entrada de aire y coloque el 5.
  • Página 17: Mantenimiento

    WL5000 Serie de modelos para contratistas PARA DESMONTAR, CHEQUEAR y Funcionamiento Mantenimiento REEMPLAzAR EL FILTRO (Continuación) Para cambiarle el filtro quítele la tapa. Saque el filtro y lávelo con agua caliente haberlo soltado o si la válvula está Libere toda la presión y desconecte la enjabonada.
  • Página 18: Guía De Diagnóstico De Averías

    Compresores de Aire Portátiles Guía de Diagnóstico de Averías Problema Posible(s) Causa(s) Acción a Tomar Compresor no funciona 1. Pérdida de potencia o se 1. Chequee el cordón de extensión adecuado (vea la sobrecalienta sección CORDONES DE EXTENSION, página 3) 2.
  • Página 19 WL5000 Serie de modelos para contratistas Guía de Diagnóstico de Averías (Continuación) Problema Posible(s) Causa(s) Acción a Tomar La presión del tanque 1. Conecciones flojas (coneciones, 1. Chequée todas las conecciones con agua enjabonada disminuye cuando el tuberías, etc.) y apriete las conecciones flojas compresor se apaga 2.
  • Página 20 A. La reparación o reemplazo dependerá del flujo normal de trabajo del centro de servicio y de la disponibilidad de repuestos. B. Si el comprador no recibe resultados satisfactorios en el Centro de Servicio a Clientes de Campbell Hausfeld. (Vea el Párrafo 2).

Tabla de contenido