Oilless
Compressors
Description
Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These compres-
sors will power spray guns, impact
wrenches and other tools. These units
operate without oil.
Safety Guidelines
This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance or call the nearest Campbell
Hausfeld Authorized Service Center.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2003 Campbell Hausfeld/Scott Fetzer
A listing of service center locations is
enclosed. Have the serial number,
model number and parts list (with
missing parts circled before calling).
DO NOT RETURN THE
PRODUCT TO THE
STOP!
RETAILER!
Record the Model and Serial numbers
(located on the compressor) and the
date of purchase in the spaces below.
Model No. ____________________
Serial No. ____________________
Date of purchase _________________
Retain these numbers for future
reference.
Do not operate
WARNING
!
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure pumping
system, the following safety precautions
must be observed at all times:
For parts, product & service information
visit www.chpower.com
WL6000 Series
DANGER
!
Breathable Air Warning
This compressor/pump is NOT
equipped and should NOT be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, you must fit
the air compressor/pump with
suitable in-line safety and alarm
equipment. This additional
equipment is necessary to properly
filter and purify the air to meet
minimal specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
IN THE EVENT THE COMPRESSOR IS
USED FOR THE PURPOSE OF
BREATHING AIR APPLICATION AND
PROPER IN-LINE SAFETY AND
ALARM EQUIPMENT IS NOT
SIMULTANEOUSLY USED, EXISTING
WARRANTIES ARE VOID, AND
CAMPBELL HAUSFELD DISCLAIMS
ANY LIABILITY WHATSOEVER FOR
ANY LOSS, PERSONAL INJURY OR
DAMAGE.
1. Read all manuals
included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the
equipment.
2. Follow all local electrical and safety
codes, as well as in the U.S.A.,
National Electrical Codes (NEC) and
Occupational Safety and Health Act
(OSHA).
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
IN221705AV 2/03
Need
Assistance?
Call Us First!
1-800-543-8622
MANUAL

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Campbell Hausfeld WL6000 Serie

  • Página 1 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. IN221705AV 2/03 © 2003 Campbell Hausfeld/Scott Fetzer For parts, product & service information visit www.chpower.com...
  • Página 2: Wheel Assembly

    Oilless Compressors 13. Fast moving air will stir up dust and Washer* General Safety (Con’t) debris which may be harmful. Nut* 5. Wear safety glasses Release air slowly when draining and use hearing moisture or depressurizing the protection when compressor system. Foot* operating the pump SPRAYING PRECAUTIONS...
  • Página 3 WL6000 Series Installation plug provided; if it will not fit outlet, MOISTURE IN COMPRESSED AIR have proper outlet installed by a Moisture in compressed air will (Continued) qualified electrician. form into droplets as it comes from with an appropriate grounding plug. WIRING an air compressor pump.
  • Página 4 Oilless Compressors REGULATOR KNOB 3. Turn power OFF and clean dust and Operation (Continued) dirt from motor, tank, air lines and 1. This knob controls air pressure to an IMPORTANT: Do not operate pump cooling fins. air operated tool, or paint spray gun. compressor before reading instructions 2.
  • Página 5: Troubleshooting Chart

    WL6000 Series Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. No electrical power 1. Plugged in? Check fuse/breaker or motor overload 2. Blown fuse 2. Replace blown fuse 3. Breaker open 3. Reset, determine cause of problem 4.
  • Página 6 8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service Center. Freight costs, if any, must be borne by the purchaser.
  • Página 7: Généralités Sur La Sécurité

    Centre Puisque le compresseur d’air et les à se servir du compresseur. De Service Autorisé Campbell Hausfeld. autres pièces détachées (pompe, MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité.
  • Página 8: Montage De Roues

    Compresseur Sans Huile Généralités sur la Purger le Rondelle* AVIS Écrou* réservoir Sécurité (Suite) quotidiennement. 4. Garder les visiteurs à l’écart de/et NE 12. L’accumulation d’humidité cause la Pied* JAMAIS permettre les enfants dans rouille qui peut affaiblir le réservoir. l’endroit de travail.
  • Página 9: Instructions De Mise À La Terre

    Series WL6000 fournie; si la fiche n’est pas la bonne Fonctionnement Installation (Suite) taille pour la prise de courant, contacter Manostat - Interrupteur Auto/Off. cordon prolongateur pour éviter une un électricien qualifié pour l’installation perte de puissance et dommage du Dans la position AUTO, le compresseur d’une nouvelle prise de courant.
  • Página 10 Compresseur Sans Huile Fonctionnement L’HUMIDITÉ DANS L’AIR COMPRIMÉ (Suite) L’humidité dans l’air comprimé forme des goutelettes en arrivant de la pompe du compresseur. Si l’humidité est élevée ou si le compresseur est utilisé ouvrant le robinet de purge situé sur la continuellement, cette humidité...
  • Página 11 Series WL6000 PROTECTEUR DE SURCHARGE COUPLE Entretien (Suite) Boulon de la bielle ..2,8 kg m THERMIQUE FILTRE D’AIR ATTENTION Boulons du compresseur . . 13,8-15,2 kg m compres- Vérifier si le filtre d’air est propre. Boulons du moteur .
  • Página 12: Guide De Dépannage

    Compresseur Sans Huile Guide De Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Le compresseur ne fonctionne 1. Manque de puissance électrique 1. Modèle branché? Vérifier le fusible/disjoncteur ou surcharge du moteur 2. Fusible sauté 2. Remplacer le fusible sauté 3. Disjoncteur déclenché 3.
  • Página 13 2. GARANTIE ACCORDÉE PAR (GARANT): Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone: (800) 543-6400 3. BÉNÉFICIAIRE DE CETTE GARANTIE (ACHETEUR): L’acheteur original (sauf en cas de revente) du produit Campbell Hausfeld. 4. PRODUITS COUVERTS PAR CETTE GARANTIE: N’importe quel compresseur d’air Campbell Hausfeld.
  • Página 14: Descripción

    Campbell Hausfeld no asumirá NINGUNA gravedad. responsabilidad por pérdidas, heridas Esto le ADVERTENCIA personales o daños.
  • Página 15: Instalación

    Serie WL6000 12. Los tanques se oxidan debido a la Informaciones Arandela* acumulación de humedad y ésto Tuerca* Generales de debilita el tanque. Asegúrese de Pata* drenar el tanque a diario y de Seguridad inspeccionar periódicamente para detectar condiciones de peligro (Continuación) como la formación de óxido y 5.
  • Página 16: Humedad En El Aire Comprimido

    Compresores Sin Aceite Instalación HUMEDAD EN EL AIRE COMPRIMIDO La humedad que se acumula en el aire comprimido se convierte en gotas a medida (Continuación) que sale del cabezal del compresor de aire. Cuando el nivel de humnedad es muy alto o cuando el compresor ha estado en uso continuo por mucho tiempo, ésta se tiene un enchufe para conexión a acumulará...
  • Página 17: Mantenimiento

    Serie WL6000 6. Gire la perilla del regulador MANOMETRO REGULADO DE LA Funcionamiento SALIDA completamente en sentido contrario (Continuación) al de las agujas del reloj , para cerrar 1. Este manómetro le permite verificar drenar la humedad del tanque diaria- el flujo de aire y coloque el la presión de salida muy fácilmente.
  • Página 18: Lubricacion

    Compresores Sin Aceite Si el protector térmico apaga el motor Mantenimiento ALMACENAMIENTO con mucha frecuencia puede ser por lo 1. Mientras no lo esté usando debe (Continuación) siguiente: almacenar el compresor y las FILTRO DE AIRE mangueras en un sitio seco y frío. 1.
  • Página 19: Guía De Diagnóstico De Averías

    Serie WL6000 Guía de diagnóstico de averías Problema Posible(s) Causa(s) Acción a tomar El compressor no funciona 1. No hay energía eléctrica 1. ¿Está conectado? Chequée el fusible/cortacircuito o protector de sobrecarga del motor 2. Fusible quemado 2. Reemplace el fusible quemado 3.
  • Página 20: Responsabilidades Del Garante Bajo Esta Garantia

    Estándard (Standard Duty) - Un año; Productos Resistentes (Serious Duty) -Dos años; Productos Robustos (Extreme Duty) - Tres años; Serie Modelo Maxus - Cinco años. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.