Installation
Install the bilge water / oil separator in an
easily recognizable position, making sure
that the separator is always above water
level and high enough to prevent the bilge
water from returning and to avoid a siphon-
ing effect. Sailboats present an additional
challenge if they are sailed under a certain
angle of heel.
Attach the separator to a vertical bulkhead.
For details concerning the primary dimen-
sions please see page 30.
The separator connections fit tubing with a
diameter of 19mm. Always use flexible tub-
ing for both connections; i. e., for the con-
nection between the bilge pump and the
separator and for the connection between
the separator and the shell duct.
Use only water and / or soap to facilitate the
attachment of the tubing to a tube column;
avoid products containing oils and fats.
Fasten the hose couplings with a stainless
steel tube clamp.
Bilge water/oil separator 'BISEP19'
Note: If the tubing is very long, install a
check valve immediately downstream of the
bilge pump to prevent repeated starting
and stopping of the bilge pump.
For details please see Fig. 3 on page 27.