Installation
Shower Dimensions
Supplies from above
Front
1
Rough-In Piping
Supply inlets are 1/2" NPT fl exible hose and are accessible from the back of the shower or from knockouts on the top cover.
Bradley's Equa-Flo valve shown; other valve versions install in similar manner.
•
If supplies will be run "thru-wall", Bradley recommends using a 90° street ell to connect the supply hoses.
•
If supplies will be run "from above", Bradley recommends running them approximately 1/2" into the top cover.
2
Install Shower
Using the shower hinge as a
template, mark wall and drill
A
holes for 1/4" fasteners (wall
anchors and fasteners
supplied by installer). Secure
hinge side to the wall.
Bradley Corporation • 215-1441 Rev. C; EN 07-304
6-3/4"
(173)
Hot
5"
(127)
6"
(152)
Supplies
Thru
Wall
13-3/4"
(349)
4"
(102)
Cold
or
Tempered
Rear
1/2"
(13)
16-3/4"
(425)
4"
(102)
22-3/4"
(579)
3-1/8"
(80)
Connect the 1/2" flexible hoses
B
to the supply lines. Turn the
water on and check for leaks
and adequate water spray.
Close the shower tight to
the wall and mark the
holes for the mounting
C
tabs on the wall. mark wall
and drill holes for 1/4"
fasteners. Secure tabs to
the wall.
See table on page 2 for recommended
showerhead heights.
4/2/07
3-1/2"
(89)
1-3/4"
(44)
1/2"
(12)
6-7/8"
(173)
WS-1X
17-3/4"
(452)
3-1/4"
(82)
1/2"
(12)
3