If you need to delete all the data contained in the memory of the control unit by using a transmitter memorized in Mode II, carry out the
procedure shown in table "A7".
!
Deletion with transmitters memorised in Mode II is a particularly complex procedure and the points below must be observed. The
procedure detailed in Table A3 is much simpler if a transmitter which has not been memorised is used.
• Deletion is not possible with transmitters which have a "MAN PRESENT" command. If necessary, a new transmitter and the procedure
detailed in Table "A3" must be used.
• Se si esegue la procedura con trasmettitori con comando TIMER è necessario partire dal punto A, altrimenti iniziare dal punto 1
You can delete:
• the transmitters only, by stopping at point 4 of the procedure;
• all the data (transmitters, TIMER 1 and TIMER2 duration), by carrying out the procedure through to point 5.
Table "A7"
Memory deletion with transmitter memorized in Mode II
A
A Switch the control unit off and cut the jumper on the weld side of the card (see fig. 12).
The jumper must be reconstituted when the deletion procedure has been completed.
B
Power the control unit and wait for the initial beeps
C
Press and hold down the key with the TIMER command. The relay will switch on, and after
approximately 3 seconds it will switch off. Proceed to point 2 keeping the key held down.
1
If the relay is OFF, press and release the key with the ON/OFF command in order to switch it on
Press the key again and keep it pressed down.
2
After approximately 5 seconds you hear a beep, then release
3
After 1 second press down the same key again and release during the third beep.
4
After 1 second press down the same key again and release during the third beep.
5
After 1 second press down the same key again and release during the third beep.
6
If you wish to delete all the data in the memory, press the same key again within 2 seconds
until you hear the first of 5 beeps, then release it.
N.B.: 5 beeps will indicate that all the codes in the memory have been deleted.
Using 3 key type transmitters "
If transmitters have keys like "▲ ■ ▼" memorised in Mode I, the "OFF" command can be associated to key ▼. for each one of them. This
makes using the "events" forecasted by the transmitters like, for example SRCW 06T, easy. Key ■ will continue carrying out the "OFF"
function.
The transmitter must be memorised in Mode I in order to enable this function, and the said function will only be enabled to that transmitter.
Repeat programming for all the necessary transmitters.
FUNCTION "ON" "OFF" with ▲ ■ ▼
Table "A8"
Press and hold down key ■ of a previously transmitter memorised in Mode I until you hear
1.
a beep (after about 5 seconds) then release it.
Within 3 seconds press simultaneously the two keys ▲ ▼ and hold them down for approx.
2.
5 seconds until 3 beeps sound to confirm the function has been programmed.
N.B.: If the user should wish to exclude the function, s/he must repeat the procedure starting from point 1.
5) What to do if...
a short troubleshooting guide!!
When the control unit is switched on, no beep sounds and
the transmitters do not transmit any commands.
Make sure that the control unit is powered correctly: there must be
mains voltage between terminals 6-7.If the power supply is correct,
there is likely to be a serious fault in the system, and the control unit
will have to be replaced.
6 beeps will sound after a radio-controlled command. The
relays will neither switch on nor off.
The radio control is out of synch, the transmitter memorization pro-
cedure must be repeated.
20
▲ ■ ▼
"
After a radio command, you hear 10 beeps and then the
relais switches on.
The self diagnosis of the parameters in the memory has detected a
fault.