Midea MLV45N1BWW Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

If you install your washer in an alcove or closet, the front of the closet
must have two unobstructed air openings for a combined minimum total
area of 72 sq.in. (465 sq.cm) with a minimum clearance of 3 in. (7.6 mm)
at the top and bottom. A slatted door with equivalent space clearance is
acceptable.
48 square inches
(310 cm )
2
24 square inches
(155 cm )
2
Installing in an alcove or closet
Minimum clearances between your washer and adjacent walls or other
surfaces are:
Either side: 1 in. (2.5 cm)
Rear: 6 in. (15.2 cm)
Closet Front: 2 in. (5.1 cm)
Top: 24 in. (61 cm)
Gap between the end of water valve and the wall:
- Case 1: If you connect the supply hose after you install your washer:
Over 3.9 in. (10 cm)
- Case 2: If you connect the supply hose before you install your
washer: Over 2.8 in. (7 cm)
If you install your washer and dryer side-by-side in a closet, the closet front
must have an unobstructed air opening of at least 72 square inches
(465 square cm).
3 in.
(7.6 cm )
3 in.
(7.6 cm )
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mlv45n3bww

Tabla de contenido