2. Introduction
2.1 Product Introduction
The Tripp Lite SRCOOL60KCW In-Row Precision Chilled Water Cooler uses a modular, parallel cabinet design that facilitates expansion
or movement and can be flexibly integrated into your data center environment. With a high cooling efficiency and the ability to be set in
an area adjacent to a heat load, the SRCOOL60KCW decreases ambient temperature in order to lower overall energy costs and prolong
equipment lifespan. As your data center grows, your increased cooling needs can be met by easy re-configuration of the equipment.
When installed in a data center, untreated air will be drawn in from the rear of the cooling unit and treated and cool air will be released
from the front of the unit.
The cooling unit is managed by a user-friendly interface. Cooling efficiency can be actively controlled with the built-in microcontroller unit
that reports abnormalities via the alarm system.
2.2 Functions and Features
y y
Intelligent temperature control
Built-in microcontroller unit accurately detects and manages the data center's temperature, automatically adjusts the unit's output,
and supports two automatic control modes, intelligent control mode (default) and PID control mode.
y y
User-friendly control interface
Provides easy setting, monitoring, and access to system configuration and status.
y y
Three-way ball valve automatic spring-resetting
During an abnormal power interruption, the inner flow-rate actuator will automatically close the three-way ball valve within 15 seconds
to stop chilled water from continuously flowing into the coil and generating condensation, which may lead to water leakage.
y y
Upper piping configuration option
Supports lower (default configuration) and upper (with SRCOOL60KTP kit, sold separately) piping for a flexible configuration.
y y
Alarm system
Detects abnormalities and reports via a buzzer, an external dry contact device, or over the TCP/IP connection.
y y
Heat load temperature detection
Accurately monitors the heat load temperature via remote temperature sensors.
y y
Water leakage detection
Optional water leakage detector (configurable up to 50 m / 164 ft.) immediately informs the user of any water leakage.
y y
Output and input dry contacts
Includes two output and two input dry contacts for fire alarm, smoke alarm, system alarm, etc.
y y
Insulated side panels
Isolates the unit from outside temperature variations.
y y
Multi-speed and hot-swappable fans
The unit is equipped with high efficiency and energy saving fans whose rotation speed is adjustable between 30~100%. Fans are hot-
swappable for uninterrupted unit operation.
y y
Lockable front / rear doors and side panels
Prevents unauthorized access.
y y
Condensed water pump
The condensed water pump automatically drains condensed water while the water level sensor at the bottom of the cabinet detects
the condensed water pan's respective water level to avoid leakage.
y y
Casters
Offer convenient movement or relocation.
y y
Network interface
Provides remote monitoring and management through SNMP protocol.
4