Festo CPV GE-ASI-4E4A Serie Instrucciones Para El Usuario página 16

Terminal de válvulas
Ocultar thumbs Ver también para CPV GE-ASI-4E4A Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
CPV..-GE-ASI-4E4A-...
2
Connecting and display elements
1
0
9
8
1
2
AS-i bus connection
3
LED status display for inputs (green)
4
Sensor connections (PNP)
5
Functional earth connection
6
Type plate (ID and IO codes)
Inscription field for AS-i address
*) Only with type CPV..-GE-ASI-4E4A-Z: Valves can be switched off during
EMERGENCY STOP, no voltage supply to valves via AS-i bus
BUS LED 1
BUS LED 2
(green)
(red)
on
out
out
out
flashes
on
out
flashes
out
on
16
2
3
Meaning
AS-i voltage applied, no fault
No AS-i voltage on bus
AS-i address not set (zero)
Short circuit/overload at the inputs
Failure of bus communication
(watchdog expired)
4
5
6
7
7
LED status display for
8
valves (yellow)
Load voltage
9
connection for valves *)
0
BUS LED 1 (green)
BUS LED 2 (red)
9807a

Publicidad

Tabla de contenido
loading

Tabla de contenido