Installation
1
Determining the mounting
location
NOTE: The light fixture should be mounted approximately
8 ft. (2.4 m) above the ground. If the light fixture is
mounted higher than recommended, aiming the sensor
down will reduce the coverage area.
□
Determine the mounting location – wall or eave
mount.
□
Position the light panels (A) in the general
direction of the desired light coverage.
□
If needed, rotate the motion sensor (C) so the
controls face the ground after installation.
Wiring the mounting plate
IMPORTANT: Push-in terminals not for reuse.
To remove the wires from the mounting plate connector, twist the wires
back and forth as the wires are being pulled from the mounting plate.
2
Connecting solid copper house
wire
WARNING: Turn the power off at the circuit breaker or
fuse. Place tape over the circuit breaker switch and verify
power is off at the light fixture.
IMPORTANT: This mounting plate is designed for solid-core 14
or 12 AWG wire. If the house wiring is stranded wire, see step 3,
Connecting stranded house wire below.
NOTE: If necessary, strip 5/8 in. of insulation from
junction box wires. Use the wire length measuring guide
on the back of the mounting plate to ensure the correct
wire length.
□
Remove the existing light fixture.
□
Insert the junction box wires (1) into the side of
the terminal block on the back of the mounting
plate (D).
□
Insert the white wire from the junction box
into the terminal marked "N".
□
Insert the black wire from the junction box
into the terminal marked "L".
□
Insert the bare or green ground wire from
the junction box into the terminal marked
"G".
□
Proceed to step 4, page 7.
Wall Mount
A
C
If the house wiring is solid copper wire, proceed with
step 2. If the house wiring is stranded copper wire,
proceed to step 3.
5/8"
1
5
Please contact 1-866-308-3976 for further assistance.
Eave Mount
HOMEDEPOT.COM
D
1