Reverse Motion

Master/Slave
Mode
Page 18 of 68
Continued from previous page
To reverse the direction of the pan and tilt motion, follow the instructions below:
1. Press <MENU> repeatedly until rEv shows blinking on the display.
2. Press <ENT> (the current option for pan direction will show (P-n or P-Y).
a. To change the setting, use <UP> or <DOWN> and continue to step "3".
b. To keep the setting, continue to step "3".
3. Press <ENT> (the current option for tilt direction will show (t-n or t-Y).
a. To change the setting, use <UP> or <DOWN> and continue to step "4".
b. To keep the setting, continue to step "4".
4. Press <ENT> (the current software version will show briefly on the display, followed
by rEv).
This mode allows a single Scorpion™ GBC EU/RBM EU/RGY EU/BLU EU fixture (the
"master") to control the actions of one or more Scorpion™ GBC EU/RBM EU/RGY
EU/BLU EU units (the "slaves") without the need of a DMX controller. The master unit
will be set to operate in either Automatic, Sound, or Laser Sky mode, while the slave
units will be set to operate in Slave Mode. Once set and connected, the slave units will
operate in unison with the master unit.
Configure the units as indicated below.
When working as a slave unit, the Scorpion™ BLU EU will duplicate all the effects
and movements of a Scorpion™ GBC EU, RBM EU, or RGY EU master unit, minus
the multiple colors.
Slave units:
1. Press <MENU> repeatedly until SLA shows blinking on the display.
2. Press <ENT> (SLA will show solid on the display).
3. Connect the DMX input of the first slave unit to the DMX output of the master unit
4. Connect the DMX input of the subsequent slave units to the DMX output of the
previous slave unit.
5. Finish setting and connecting all the slave units.
Master unit:
1. Set the master unit to operate in either, Automatic, Laser Sky, or Sound mode, as
previously indicated.
2. Make the master unit the first unit in the DMX daisy chain.
Wait until all the slave units are configured and connected before connecting
the master unit to the DMX daisy chain.
Never connect a DMX controller to a DMX string configured for Master/Slave
operation because it may interfere with the signals from the master unit.
Do not connect more than 31 slave units to the master unit.