18. Install the shielding mesh
Wrap a half-lapped layer of the mesh across the entire splice and
tie off.
Abrade and solvent clean cable jackets as shown to provide an oil-
free surface.
19. Apply red sealant
Remove release paper from red sealant and place one full wrap at
cable jacket cutbacks as shown.
20. Position wraparound sleeve
Remove or tape over all sharp points to prevent puncture of
wraparound sleeve. Remove backing from wraparound sealing
sleeve and center sleeve over splice. Slide metal retention clip onto
the butted rails.
21. Install channels
Connect the channels by overlapping the retention clip as shown
at right.
Note: Channels must overlap sleeve edge by 1/4 inch minimum.
If channels slide on easily go to step 22. If channel fit seems tight,
continue with next paragraph.
As shown in illustration A, make sure flap is not pinched between
the rails. Push the sleeve up from the bottom and down from the
top while sliding on channel as shown in illustration B. The idea is to
flatten the rails together to prevent the channels from binding.
PII 53106
Revision AL
Clean
Shielding Mesh
8"
(200mm)
Tubo Nergro/Rojo de Triple Capa
Wraparound Sleeve
Manga Termocontractil Negra/Verde
Channels slide over
retention clip
1/4" min.
7
Triple Layer Tube
1 wrap
Red Sealant
Retention Clip
Retention
Clip
1/4" min.
A
B
PCN 690615-000
Effective Date: June 17, 2010
Clean
8"
(200mm)
124
124a
125
126