Activate cleaning
and diagnosis
beeeep
1.
beeeep
2.
beeeep
3.
beeeep
4.
Battery monitor
beeeep
2 seconds „beep" prior
flushing
--> weak batteries
Action item: Replace battery
shortly
beeeep
2 seconds „beep" after use
of urinal, no flushing
--> dead batteries
Action item: Replace battery
immediately
DE/FR/IT/EN/ES/NL
Explanation of symbols
Place the mag-
netic key on the
logo and hold it
there
Now remove the
magnetic key
from the logo
again
Cleaning programs
5 minute suspension: The flushing program
beeeep
stops for 5 minutes ("beeps" during the pause) to allow the urinal
beeeep
to be cleaned manually. The complete rinse is now activated.
The control unit switches back to its pre-set mode.
beeeep
Full flush: A flush is activated. The control unit
beeeep
switches back to its pre-set mode.
beeeep
Interval cleaning: The control unit initiates
beeeep
5 short flushes at preset intervals of 2 minutes.
This allows, for example, descaler to work.
Finally there is a full flush, after which the control
unit returns to the pre-set mode.
beeeep
Diagnosis of system
beeeep
(approx. 10 seconds)
8
beeeep
1 x „beep" + flush = system o.k.
1 x „beep" no flush = solenoid valve
problem
Please check:
1. Connection control unit <-> solenoid
valve
2. Water supply
3. Solenoid valve
beeeep
2 x „beep" = sensor problem
beeeep
Please check:
1. Connection control unit <-> sensor
2. Sensor
3. Electronic module
beeeep
3 x „beep" = Weak batteries: Replace
beeeep
beeeep