Amate Electroacústica,s.l.
Fig.3. Example of applying the HFC
2.3. Connection Panel
A) BALANCED INPUT: XLR balanced signal connector.
1= Shield
2= Live
3= Return
B) LINK: XLR connector for parallel connection of various cabinets with the same
input signal.
1= Shield 2= Live
3= Return
C) AC MAINS: Mains supply via PowerCon
D) AC LINK: Power link for PowerCon connector to feed other units in parallel (up to
a maximum of 5 extra units).
E) 90Hz filter: High-pass filter at 90Hz for better coupling with subwoofer.
F) POWER ON: lights up with correct AC signal.
G) LIMITER: Prevents the amplifier outputs from overdriving the transducers. When
the LIMITER indicators are active, they are in red colour. The LIMITER indicators can
be in red occasionally, but if they are continuously activated, turn down the level
control until the LIMITER indicators are only in red occasionally.
H) HF output level: -3dB/0dB/3Db high frequency output level control.
PA208A.Ver 1.0
May 09
19