5 HARDWARE INSTALLATION
5.5 Installing a Leviton MDA Splicing Deck
Install an HDF3168 MDA Splicing Deck by following these steps:
5.5.1 Select the target rack unit location and thread the provided 12/24 screws 3-4 turns in the
correct holes.
5.5.2 Place the Deck over the screws and while supporting with one hand tighten each screw
to hand tight torque (Figure 9).
5.5.3 Verify unobstructed movement of each tray.
5.5.4 Attach the rear routing guide on to the rear mounting rail (Figure 10).
5.5.5 Facing the front of the mounted Deck, place the cable management louver over the
screws on the left hand side (Figure 11) and attach with a hand tool only. DO NOT
OVER TIGHTEN.
5.6 Installing a Leviton MDA Splice Deck Tray
All Splice Deck Trays are inserted and removed from the rear. To install an HDF3168 MDA Splice
Deck Tray by following these steps:
5.6.1 Remove the label window from each Splice Deck Tray.
5.6.2 Starting from the bottom of the deck, insert the three trays in the perspective deck guide
slots.
5.6.3 Slide each tray forward until the label window mounting tabs are accessible (Figure 16).
5.6.4 Re-install each label window and return the tray to the closed position.
Figure 16
24