1.5.6
Logic funcionality Varc (WIN TIG)
The Kit art. 449.00, installed inside the Power Source, allows the power source output voltage reading,
devoid of the high voltage / high frequency (HF) pulses required for the arc striking.
This signal can be used by the installer as a feedback volt- age for the CNC or PLC.
Obviously, as a function of the input parameters of the used digital controller, the signal will have to be
appropriately attenuated (by the installer).
1.5.7
Elettric diagram
3301060/A
13
ES
16/11/2020