Pressure Sensors with IO-Link
BSP-B... /-V...
Mechanical installation
Important notes for installation of flush-mounted
sensors:
Caution!
Handle the unprotected membrane with the
utmost care: it can be easily damaged.
Do not remove the packaging and protective cap until
shortly before installation, so that the membrane
remains undamaged. Retain the protective cap.
After disassembly, place the protective cap back over
the membranes immediately.
Do not use force when installing the sensor, so as not
to cause damage to the device or the system.
Fig. 1: Unprotected membrane of the flush-mounted sensor
Installation of connections according to DIN 3852
Make sure that:
The sealing surface on the relevant part is perfectly
clean and free of residues,
The O-ring seated in the slot provided is undamaged.
1. Screw the device into the mounting thread by hand.
Secure devices to the steel pressure connection using
a flat wrench. Observe the following torque values:
Torque
Connection
per
EN 3852
1/4"
approx. 5 Nm approx. 20 Nm approx. 30 Nm
1/2"
approx. 10 Nm approx. 50 Nm approx. 70 Nm
2
English
Membranes
Connection
NPT
per
connection
EN 837
Fig. 2: Electrical connection and process connection
Fig. 3: Display and connection housing rotate 320°
Fluid
Fig. 4: Process connection for the flush-mounted sensor (G1/2" in
accordance with EN 3852)
Adapter for process
connection
Flush-mounted
sensor
Factory-set
connection G1/2"