Pressure Sensors with IO-Link
BSP-B... /-V...
IO-Link interface
Parameterization data
The pressure sensor parameter data corresponds to the smart sensor profile.
Index
Subin-
Object name
hex
dex hex
0x02
0x00
System com-
mands
0x03
0x00
Data storage
index
0x0C
0x00
Device access
lock
0x24
0x00
Device status
0x3D
0x02
Switch point
mode
0x3F
0x02
Switch point
mode
0x50
0x00
Rotate display
0xD4
0x00
Unit
10
English
Single Value
0x81 = Deleting Min./Max. value
0x82 = res
0xA0 = Set0
0x01: Start upload
0x02: End upload
0x03: Start download
0x04: End download
0x05: Data storage break
0x00: Unlocked
0x01: IO-Link lock
0x02: Data storage lock
0x04: Parameterization lock
0x08: User interface lock
0x03: IO-Link lock + Data storage lock
0x05: IO-Link lock + Parameterization lock
0x09: IO-Link lock + User interface lock
0x06: Data storage lock + Parameterization lock
0x0A: Data storage lock + User interface lock
0x07: Data storage lock + IO-Link lock + Param-
eterization lock
0x0B: Data storage lock + IO-Link lock + User
interface lock
0x00 Device is operating properly
0x02 Out of specification
0x04 Failure
0x80: Hysteresis NO
0x81: Hysteresis NC
0x82: Window NO
0x83: Window NC
0x80: Hysteresis NO
0x81: Hysteresis NC
0x82: Window NO
0x83: Window NC
0x01 0°
0x00 180°
0x00 bar
0x01 mbar
0x02 PSI
0x03 MPa
Default
Comment
The action is
carried out by
writing in the
subindex.
0x00:
Unlocked
0x80: Hno
0x80: HNo
0x01: 0°
0x00: bar
Display pressure
unit is changed,
the IO-Link pro-
cess data is not
changed