Factory Settings - Balluff BSP B S1B Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Pressure Sensors with IO-Link
BSP-B... /-V...
Overview of adjustable parameters
Menu item
Menu 1
SP1 / FH1
Menu 2
rP1 /FL1
Menu 3
SP2 / FH2
Menu 4
rP2 /FL2
Menu 5:2
dS1
Menu 5:3
dr1
Menu 5:4
dS2
Menu 5:5
dr2
Menu 5:6
ou1
Menu 5:7
ou2
Menu 5:8
uni
Menu 5:13
dAP
Menu 5:14
code
8
English
Description
Switching point 1/
FH 1
Return point 1 /
FL 1
Switching point 2/
FH 2
Return point 2 /
FL 2
Switching
delay time 1
Return
delay time 1
Switching
delay time 1
Return
delay time 1
Switching function
Output 1
Switching function
Output 2
Units
Measure value damping
Password

Factory settings

80%
of the nominal pressure
75%
of the nominal pressure
80%
of the nominal pressure
75%
of the nominal pressure
0 sec
0 sec
0 sec
0 sec
Hno
Hno
bar
0 ms
0000