Problem
The pump does not start or run.
The pump operates but pumps little or
no water.
The pump starts and stops too often.
The pump will not shut off.
Possible Cause
1. The fuse is blown.
2. The breaker is tripped.
3. The plug is disconnected.
4. The plug is corroded.
5. There is thermal overload.
6. The switch failed.
7. The motor failed.
1. The screen is blocked.
2. Debris is caught in the impeller or discharge.
3. The impeller is loose on the shaft or the
impeller is broken.
1. There is a backflow of water from the piping or
the check valve is leaking.
2. The float switch is stuck.
1. The switch is tangled.
2. The float switch is faulty.
3. The float is obstructed.
9
Corrective Action
1. Replace the fuse.
2. Reset the breaker.
3. Secure the plug.
4. Clean the plug prongs.
5. Unplug for 30 minutes and then plug
in again.
6. Replace the switch.
7. Replace the pump.
1. Clean the screen.
2. Remove the debris.
3. Reassemble the impeller or replace
the impeller.
1. Install a check valve or replace the
check valve.
2. Clean the float switch to make sure
the float moves up and down freely.
1. Reposition the pump and make sure
the switch moves freely.
2. Replace the switch.
3. Remove the obstruction.