Make Electrical Connection - Kohler MasterShower K-75 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

H. SECURE TOWER ASSEMBLY:
1.
See Fig. #18 . After handle is installed, secure the four
latches: align 1/8" hex head wrench into latch, push in on
tower, and rotate latch 1/2-turn.
Latch (1 each side)
1/8" Hex
Wrench
Latch
(1 each side)
A
1017708-2-
Fig. #18
I. MAKE ELECTRICAL CONNECTION:
Transformer is not supplied with K-75-JA. Properly
wire a transformer with output voltage of 12 VAC +/- 5% @ 5A.
1.
Have a licensed electrician connect the transformer leads
from the shower tower power cord and make a routine service
connection to the transformer. See Fig. #19 .
Transformer
Blue
Blue
Black
White
Risk of electrical shock. Disconnect power
before installing or servicing transformer.
1.
Remove the transformer enclosure cover.
2.
Place strain relief bushing on SJO cord from shower tower
assembly. Feed power cord through upper port on the
transformer enclosure. Allow ample cord for connection and
tighten strain relief bushing.
3.
Attach leads as illustrated.
4.
Supply 120 VAC power line with strain relief bushing. (See
Specifications on first page.) Feed incoming power line
through one of the lower knockouts on the transformer
enclosure. Allow ample line for connection and tighten strain
relief bushing.
5.
Attach leads as illustrated.
8
Black
12 VAC
To TB1 Connector
White
18/2 SJO Cord
Strain Relief
Not Provided
120 VAC
Supply Voltage
Earth
Strain Relief
Ground
Not
Provided
Fig. #19
Kohler Co.