12/48 Bosch Rexroth AG | Electric Drives and Controls
4 Mounting Instructions
Unqualified repairs or operations on the hard-
ware or software or the failure to observe the
warnings in these instructions or warnings
placed on the product itself could lead to per-
sonal injury or damage to equipment.
Qualified personnel are:
– Project personnel, familiar with the safety
regulations of automation systems and
electrical engineering.
– Operators, instructed in the use of the
equipment and having knowledge of the
relevant operational parts of this docu-
mentation.
– Commissioning personnel, authorized
to set electric circuits and machines/sys-
tems into operation, ground and mark
them, according to the accepted rules of
safety and current technology.
Repairs and replacement of parts carried out
by the user are his own responsibility. After
repairing or replacing parts, all prescribed
functional and safety checks must be carried
out.
KE312 | 3 609 929 987/1.0
4
Mounting Instructions
The KE312 communication unit is to be in-
serted into the slot provided in the SB/
SBH301 system box.
3 Min
Make sure that the communication unit is
completely inserted.
The front knurled bolts must be tightened.
Make sure that the front panel fits tightly to
the SB/SBH301 by tightening the knurled
bolts.
Before the communi-
cation unit is inserted,
the SB/SBH301 must
be switched to neutral
and a discharging time
of ≥ 3 minutes must be
taken into account.
Otherwise the time
until the next restart is
approx. 30 seconds.