LED Wall Pack
Fixture Diagram
Figure 1
Figure 2
D
GR
GND
A
Cautions:
IMPORTANT: Read before removing fixture from carton. Retain
for future reference.
SAFETY: This fixture must be wired in accordance with the
NATIONAL ELECTRICAL CODE (NEC) and applicable local codes
and ordinances. A person familiar with the construction and
ING CHECKLIST: If the light does not work.
operation of the product and the hazards involved must install
this product. A qualified licensed electrician should complete all
work. Proper grounding is required for safety.
WARNING: Make certain power is OFF before installing or
maintaining fixture.
RISK OF INJURY: Fixture may become damaged and/or unstable
if not installed properly.
Electrical Requirements
The LED driver must be supplied with 120 to
277V, 50/60 Hz and connected to an individual,
properly grounded branch circuit protected by a
20 Ampere circuit breaker. Use min. 90°C supply.
Grounding Instructions
The grounding and bonding of the overall
system shall be done in accordance with
NEC Article 600 and local codes
R
ISK OF FIRE, EXPLOSION AND ELECTRIC SHOCK
• This product should be installed, inspected, and maintained by a qualified
electrician only, in accordance with the NEC (National Electric Code) and all
local codes.
• Turn off electrical power before inspection, installation or removal.
• Use only UL (or other NRTL) approved wire for input/output connections.
Minimum size 18 AWG or 14 AWG for continuous runs.
• Make sure LEDs and drivers are cool to touch when performing maintenance.
Make sure the supply voltage is the same as the rated voltage of the luminaire.
• Do not install in a hazardous atmosphere, except where the ambient
temperature does not exceed the rated operating temperature of the fixture.
• Keep tightly closed when in operation
FCC Information:
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including
interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
D
A
C
GR
B
31/4" OCT.BOX
TEMPLATE
4" OCT. BOX
A
For warranty information please visit: http://www.kichler.com/warranty
Para informacion de la garantia por favor visite: http://www.kichler.com/warranty
Installation Instructions:
NOTE: Turn off electrical supply at the breaker. Follow all
local electrical codes for wiring and grounding requirements.
NOTE: This fixture is intended to be surface mounted on to a
wall in the lens down position.
Tools Required: Phillips Screw Driver, Security Torx T-20 Bit
& Driver, Electric Drill, Drill Bit Set, Wire Strippers & Cutters
1) Unpack fixture and ensure that there are no damaged
parts.
2) Open fixture by removing the T-20 Security Torx screws on
the side of the fixture.
3) Disconnect orange connector and remove LED and frame
assembly to allow for easier installation.
D
4) Inspect the 3 mounting hole locations (Item A on fig. 2)
and ensure that there are no components over them.
5) In order to mount the fixture the backplate has to be
pierced at the mounting locations. Use an appropriate
sized drill bit for the mounting screws up to 5/16".
6) Align the backplate and mount securely with mounting
hardware appropriate for surface.
7) If electrical connections are going to be made from a
conduit pipe, remove one of the conduit plugs from the
base and thread NPS conduit pipe into location.
8) If electrical connections are going to be made through a
junction box, drill the appropriate holes (Item C in Fig.2)
for the sized junction box.
9) Connect leads from back of fixture to the power supply
leads: Green to green (ground), black to black (hot), white
to white(neutral).
10) Reattach frame and glass assembly to base by slipping it
over the barrel pins.
11) Reconnect orange connector and reattach the frame
assembly using the Torx Screw.
MOUNTING:
The back plate has a cast-in drill and knock-out template
to match any standard recessed junction box, three 5/16"
knock-outs for mounting holes A and three 1/2" NPS
tapped holes D for surface conduit or photocontrol unit.
A – 5/16" Diameter Knockouts
B – 9/16" Diameter Knockouts
C – Knockouts for #10 screw
D – 1/2" NPS Tapped Holes
Use weatherproof silicone sealant to seal all holes and
gaps between fixture and mounting surface.
However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
866-558-5706
We're here to help
Hrs: M-F 9am to 5pm EST
Black
Line
FIXTURE
White
Neutral
Green
Ground
IS-16232-US

Publicidad

loading

Resumen de contenidos para Kichler 16232

  • Página 1 • Consult the dealer or an experienced radio/TV technician for may cause harmful interference to radio communications. help. For warranty information please visit: http://www.kichler.com/warranty Para informacion de la garantia por favor visite: http://www.kichler.com/warranty IS-16232-US...
  • Página 2 866-558-5706 Estamos aquí para ayudarle Horario: Lunes-Viernes 9am a 5pm EST (hora oficial del este) Guía de Instalación de Kichler 16232 y 16233 Iluminación LED de pared para exteriores Diagrama del Artefacto Figura 2 Figura 1 VERDE VERDE A TIERRA CAJA OCT.
  • Página 3 866-558-5706 We’re here to help Hrs: M-F 9am to 5pm EST Kichler 16232 & 16233 Installation Guide LED Wall Pack Installation Instructions: Fixture Diagram NOTE: Turn off electrical supply at the breaker. Follow all Figure 1 local electrical codes for wiring and grounding requirements.
  • Página 4 Consulter le revendeur ou un technicien radio/télé et utilisé selon les instructions, peut causer de l’interférence d’expérience. nuisible aux communications de radio. For warranty information please visit: http://www.kichler.com/warranty Pour de plus amples informations sur la garantie, veuillez visiter : http://www.kichler.com/warranty IS-16232-CB...

Este manual también es adecuado para:

16233