8/28 Bosch Rexroth AG | Electric Drives and Controls
1 Technical Data
1
Technical Data
Designation
Order number
Admissible ambient temperature
Admissible relative humidity when in operation
Admissible storage temperature
Admissible relative storage humidity
Interference suppression
Resistance to jamming
Dimensions (B x H)
Table 1:
Subject to alteration
2
Use as Intended
The rack coupler RK300 is implemented as
plug-in module to be inserted into the bus
back of the card-rack BT300. RK300 is then
inserted into the card-rack BT300, when for
setting up a multichannel tightening system,
more than one BT300 must be connected
with each other by means of bus lines BLxxx.
For this, RK300 is realised as the drive modu-
le. In such a multi channel tightening system
the first and the last card rack in line have to
be terminated by termination resistors
AW300.
3
Safety Notes
Please keep this Technical Information in a
place easily accessible for all users.
The Technical Information is intended for
specially trained personnel who have special
knowledge of this machine's hardware com-
ponents.
Repairs or other operations on the hard or
software of our products, if they are not de-
scribed within these instructions, may only be
carried out by Rexroth experts. Unqualified
repairs or operations on the hard or software
RK300 | 3 609 929 716/1.2
RK300
0 608 830 184
0 up to 55 °C with ventilator module
20 % up to 90 % non-condensing
–20 °C up to 70 °C
20 - 95 %
EN 55011 class A (industrial range)
IEC 1000-4 part 2 up to part 5 intensity 4
57 mm x 70 mm
or the failure to observe the warnings within
these instructions or warnings placed on the
product itself could lead to personal damage
or damage to property.
Qualified personnel are
– project personnel, familiar with the safety
regulations of automation systems and
electrical engineering,
– operators, instructed in the use of the
equipment and having knowledge of the
relevant parts of this documentation refer-
ring to operation,
– commissioning personnel authorized to
set electric circuits and machines/sys-
tems into operation, earth and mark them,
in accordance with the regulations of se-
curity technology.
Repairs and replacement of parts carried out
by the user take place on his own responsi-
bility. After repair or replacement of parts, all
prescribed functional and safety checks must
be carried out.