4 Mounting Instruction

4
Mounting Instruction
RK300 is inserted into the card-rack.
3 Min
Figure 1:
At the top right, RK300 is inserted into the
provided interface of the bus back board of
BT300.
After inserting, the seat of RK300 must be
secured with two bolts.
Electric Drives and Controls | Bosch Rexroth AG 9/28
Before inserting the
rack coupler, the tigh-
tening system must be
switched to neutral.
5

Initial Operation

Before commissioning, the proper seat of all
jumpers must be ensured.
The first and last card rack should be closed
off with AW300 termination resistors, Parts
No. 0 608 830 192.
The trouble-free operation of the tightening
system can only be guaranteed, if the card
rack connection is closed off with the termi-
nation resistors.
Figure 2: Termination resistors AW300 at first and
last card rack in line.