INTRODUCTION
How it Works:
This Humidifier is designed to quietly provide visible warm moisture. Water is released from
the water tank into the boiling chamber. The boiling action helps separate minerals from
the water and kill bacteria, providing purified warm moisture.
Your humidifier is made up of these parts:
Medicine Cup
Outlet Grille
Top Housing
Mist chimney
Water Release
Float
Mist Dome
Main Housing
Boiling Chamber
Humidistat
Refill/Reset Light
Power Light/
Switch
Up to 95% bacteria free steam test results as follows:
Based on Intertek Testing Services NA Inc Independent Laboratory Testing Report 100982403COL-001.
Results are based on the reduction of the following bacteria after 2 hours of continuous use:
E.Coli: up to 99.3% after 2 hours of continuous use
S. Epidermis: up to 99.9% after 2 hours of continuous use
P.Fluorescens: up to 95.6% after 2 hours of continuous use
2
SETTING UP YOUR HUMIDIFIER
Remove from box
Remove packaging material. Set aside instruction manual.
Recycle packaging materials or save for storage.
Ensure Proper Assembly
Remove top housing. Remove tape from water release float. Make
sure float and mist dome/mist chimney are securely in place. Remove
twist tie from power cord and extend power cord full length. Do not
Filling Area
operate humidifier with power cord coiled or tied or if its power cord
is damaged. See page 6 for detailed assembly information.
Placement
Select a firm, level location at least 12" (30cm) from any walls.
Place the humidifier on a water-resistant surface.
Manufacturer will not accept responsibility for property damage
caused by water spillage.
WARNING KEEP OUT OF REACH OF CHILDREN. This product produces HOT STEAM
and should be placed in an area not accessible to children or pets with the power
cord also securely out of reach.
FILLING / RE-FILLING
Water Tank/
Step 1
DO NOT Pour Here
Reservoir
1. Pour as much as 1.3 Gallons (4.9 L) of water into the fill area located on the top of the unit.
2. You can continue to refill the humidifier even if the unit has not run out of water.
DO NOT ADD LIQUID INHALANT TO THE WATER.
DO NOT POUR WATER INTO THE OUTLET GRILLE OR BOILING CHAMBER.
ADDING LIQUID INHALANT
This humidifier can be used with liquid inhalants such as Kaz Inhalant or Vicks VapoSteam.
Inhalant should be used in the medicine cup only. DO NOT ADD LIQUID INHALANT TO THE WATER.
1. Turn humidifier off, unplug and allow to cool for 20-30 minutes.
2. Add 1 tablespoon of liquid inhalant to the medicine cup.
3. With dry hands plug unit in and proceed to following unit
operating instructions.
4. When no longer using inhalant remove liquid residue left from
inhalant by using a soft dry cloth to wipe out. Note: Liquid
will remain in medicine cup even after inhalant scent
has been dispersed into the air.
Step 2
Max Fill Line
Pour
Here