14.3
Disposal
Observe national waste disposal regulations. Do not dispose of the machine,
machine components or operating materials in residual waste. If necessary,
contact your local authorities for information on available disposal options.
If you buy a new machine or an equivalent machine from your retailer, he is
obliged in certain countries to dispose of your old machine properly.
15
TROUBLESHOOTING
Danger due to electrical voltage! Manipulating the machine when connected to the
power source can cause serious injury or death. Always disconnect the machine from
the power supply before troubleshooting and secure it against unintentional restarting!
Repair work may only be carried out by qualified personnel!
Problem
Motor does not start
Machine stops during
operation
HOLZMANN MASCHINEN GmbH
Possible cause
- No voltage in the power
supply system
- The tool is too blunt and
overloads the motor
- One phase does not
conduct current (400V)
- Tool is incorrectly applied
to the workpiece
www.holzmann-maschinen.at
W A R N I N G
- Check fuse box
- Disconnect the power plug,
- Have an electrician check it
- Sharpening tools
- Inspection of all leading
- Obtaining and applying
TROUBLESHOOTING
Remediation
check and use a new cable if
necessary
phases and supply lines by a
specialist
information on turning
techniques
30
VD 1100N