Descargar Imprimir esta página

Omnifilter D Serie Instrucciones De Instalación página 4

Filtro de agua para toda la casa

Publicidad

Idiomas disponibles

Idiomas disponibles

PROCEDURE FOR CARTRIDGE ChANGE
1.
Place a pan under the unit to catch any spilled water and
open the nearest faucet.
2.
Turn the filter top (using the blue wrench supplied
with the cartridge) clockwise about 45° to "OFF"
(see Figure 4).
4
3.
Fit the wrench onto the ribs of the tank and turn it slowly to
the left to release the pressure and loosen the tank.
4.
Support the tank as you unscrew it. Pour out the water from
the tank and remove and discard the old cartridge. Wipe the
inside of the tank clean and dry with a soft cloth.
5.
Insert a new cartridge into the tank, making sure that it seats
over the center post on the tank bottom.
6.
Lubricate the tank O-ring with a good grade of silicone
grease or food-grade vegetable oil and check it for damage.
If cut, abraded, or stretched, replace it with a new one.
7.
Screw the filter tank back onto the filter housing.
Hand-tighten the tank. DO NOT OVER TIGHTEN.
8.
Turn the top of the filter to "FILTER" with the filter wrench.
OMNIFILTER REPLACEMENT CARTRIDGES
Cartridge
Media
Reduces Sediment
Reduces Chlorine Taste & Odor
Filter Capacity
Recommended Flow Rate
Well Water Use
*Nominal: Smaller micron rating equals finer filtration.
†Not performance Tested or Certified by NSF in these housings.
•  •
3628 1199
TO1†
RS2†
Carbon Wrap
String Wound
5 Micron*
5 Micron*
yes
no
15,000 gal
15,000 gal
3 months
3 months
5 gpm
5 gpm
19 Lpm
19 Lpm
No
Yes
NOTICE: If the tank O-ring leaks after you have tightened the
tank with the wrench, DO NOT tighten it anymore. Instead,
loosen it and make sure that the cartridge is seated over the
center tube in the head assembly (not pushing against it). After
centering the cartridge, re-tighten the tank and again check for
leaks.
9.
Open a faucet for about 10 minutes to allow any
accumulation of air, fines, etc., to flush out.
NOTICE: Use only genuine OMNIFILTER replacement cartridges
for best results. Failure to use OMNIFILTER replacement
cartridges will void your warranty.
TO ByPASS ThE FIlTER
When watering lawns or doing other projects that don't require
filtered water, the U25 Series D Complete Household Water Filter
System can be bypassed.
1.
Turn the filter top (using the blue wrench supplied with the
cartridge) clockwise about 45° to "BY-PASS". Refer to Figure
5 under the "Procedure for Cartridge Change." section.
2.
To continue use of the Filter System, turn the filter top
(using the blue wrench supplied with the cartridge) counter-
clockwise about 45° to "FILTER".
RS14†
RS1†
Pleated
Polyspun
Celllulose
10 Micron*
20 Micron*
no
no
10,000 gal
15,000 gal
2 months
3 months
5 gpm
5 gpm
19 Lpm
19 Lpm
Yes
No
4
1
2
3
3
2
5
6
7
8
Assembly Parts
Key No.
Part Description
1
3/4" Compression Nuts
2
3/4" Compression Sleeves
3
3/4"–3/4" Compression Fittings
4
Multi-Purpose Wrench
5
Head Assembly
6
Tank O-Ring
7
Filter Housing Sump
8
Filter Cartridge
1
Qty.
2
2
2
1
1
1
1
1